Filter Catalog Flat roof / shed roof

General Information

Consider the spectrum adaptation term:
Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 5 of 7. There were 127 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation Values of footfall sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

F0109

Ribs / rafters 625 mm 65 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between the supporting structure of covering 102 kg/m2 -5 dB
Calculation ≈ 0.123 W/m2K -13 dB
Detail IFC4 LOD300 XLSX

F0110

Ribs / rafters 705 mm 68 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between the supporting structure of covering 110 kg/m2 -5 dB
Calculation ≈ 0.106 W/m2K -13 dB
Detail IFC4 LOD300 XLSX

F0111

Ribs / rafters 394 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between and on supporting structure with covering 240 kg/m2 -2 dB
Calculation ≈ 0.198 W/m2K -7 dB
Detail IFC4 LOD300 XLSX

F0112

Ribs / rafters 434 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between and on supporting structure with covering 244 kg/m2 -2 dB
Calculation ≈ 0.175 W/m2K -7 dB
Detail IFC4 LOD300 XLSX

F0113

Ribs / rafters 474 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between and on supporting structure with covering 248 kg/m2 -2 dB
Calculation ≈ 0.157 W/m2K -7 dB
Detail IFC4 LOD300 XLSX

F0114

Ribs / rafters 534 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between and on supporting structure with covering 253 kg/m2 -2 dB
Calculation ≈ 0.136 W/m2K -7 dB
Detail IFC4 LOD300 XLSX

F0115

Ribs / rafters 614 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between and on supporting structure with covering 261 kg/m2 -2 dB
Calculation ≈ 0.115 W/m2K -7 dB
Detail IFC4 LOD300 XLSX

F0116

Ribs / rafters 486 mm 58 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 96 kg/m2 -5 dB
Calculation ≈ 0.187 W/m2K -13 dB
Detail IFC4 LOD300 XLSX

F0117

Ribs / rafters 526 mm 60 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 100 kg/m2 -5 dB
Calculation ≈ 0.166 W/m2K -12 dB
Detail IFC4 LOD300 XLSX

F0118

Ribs / rafters 566 mm 63 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 104 kg/m2 -5 dB
Calculation ≈ 0.15 W/m2K -13 dB
Detail IFC4 LOD300 XLSX

F0119

Ribs / rafters 626 mm 65 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 109 kg/m2 -5 dB
Calculation ≈ 0.13 W/m2K -12 dB
Detail IFC4 LOD300 XLSX

F0120

Ribs / rafters 706 mm 68 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 117 kg/m2 -4 dB
Calculation ≈ 0.111 W/m2K -12 dB
Detail IFC4 LOD300 XLSX

F0121

Hollow box element 519 mm 65 dB 49 dB
Use and protection layer 2: Garden plates
Use and protection layer 1: Fine gravel 3-6 mm
Under the roof: Roofing underlay
Exterior insulation layer 1: ISOVER EPS insulation board DEO ie, DAA ie, DAD ie
Separating layer / temporary roof: Vapor barrier bituminous
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Lower skin layer 1: Lignatur surface element sheathing below

Insulation on supporting structure 241 kg/m2 -2 dB -2 dB
Measurement ≈ 0.127 W/m2K -6 dB 5 dB
Detail IFC4 LOD300 XLSX Test report PDF

F0122

Hollow box element 582 mm 60 dB 36 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Garden plates
Under the roof: Roofing underlay
Exterior insulation layer 1: ISOVER EPS insulation board DEO ie, DAA ie, DAD ie
Separating layer / temporary roof: Vapor barrier bituminous
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Lower skin layer 1: Lignatur surface element sheathing below

Insulation on supporting structure 243 kg/m2 -1 dB -2 dB
Measurement ≈ 0.119 W/m2K -5 dB 10 dB
Detail IFC4 LOD300 XLSX Test report PDF

F0123

Hollow box element 537 mm 50 dB 45 dB
Use and protection layer 2: Garden plates
Use and protection layer 1: Props screw for hollow floor
Under the roof: Roofing underlay
Exterior insulation layer 1: ISOVER EPS insulation board DEO ie, DAA ie, DAD ie
Separating layer / temporary roof: Vapor barrier bituminous
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Lower skin layer 1: Lignatur surface element sheathing below

Insulation on supporting structure 198 kg/m2 -2 dB -4 dB
Measurement ≈ 0.103 W/m2K -6 dB 2 dB
Detail IFC4 LOD300 XLSX Test report PDF

F0124

Hollow box element 350 mm 40 dB
Use and protection layer 1: Protective layer
Under the roof: Roofing underlay
Exterior insulation layer 1: Bauder PIR diffusionsdicht
Separating layer / temporary roof: BauderTHERM DS 1 DUO
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Lower skin layer 1: Lignatur surface element sheathing below

Insulation on supporting structure 38 kg/m2 -2 dB
Measurement ≈ 0.121 W/m2K -5 dB
Detail IFC4 LOD300 XLSX Test report PDF

F0125

Hollow box element 409 mm 50 dB
Under the roof: Roofing underlay
Exterior insulation layer 1: Flumroc insulation board PRIMA
Separating layer / temporary roof: BauderTHERM DS 1 DUO
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Lower skin layer 1: Lignatur surface element sheathing below

Insulation on supporting structure 61 kg/m2 -1 dB
Measurement ≈ 0.139 W/m2K -7 dB
Detail IFC4 LOD300 XLSX Test report PDF

F0126

Hollow box element 479 mm 53 dB
Use and protection layer 2: Fine gravel 3-6 mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Expanded polystyrene (EPS)
Separating layer / temporary roof: BauderTEC KSA
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Lower skin layer 1: Lignatur surface element sheathing below

Insulation on supporting structure 113 kg/m2 -1 dB
Measurement ≈ 0.158 W/m2K -6 dB
Detail IFC4 LOD300 XLSX Test report PDF

F0127

Hollow box element 499 mm 64 dB
Use and protection layer 2: Gravel 8-16mm
Under the roof: Roofing underlay
Exterior insulation layer 1: ISOVER EPS insulation board DEO ie, DAA ie, DAD ie
Separating layer / temporary roof: Vapor barrier bituminous
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Lower skin layer 1: Lignatur surface element sheathing below

Insulation on supporting structure 166 kg/m2 -2 dB
Measurement ≈ 0.127 W/m2K -6 dB
Detail IFC4 LOD300 XLSX Test report PDF

F0130

Hollow box element 534 mm 62 dB
Use and protection layer 3: Gravel [partially broken] 16-32mm
Use and protection layer 1: Concrete panels
Seal: Elastomerbitumen-Dichtungsbahn Sopravap EVA 35 flam
Exterior insulation layer 2: Expanded polystyrene (EPS)
Exterior insulation layer 1: Concrete panels
Separating layer / temporary roof: Crumb rubber mat
Sheathed above 1st layer: Querrost oben zu Block Lignotrend Q3 (b=65mm e=125mm)
Support: Block Lignotrend Q3
Lower skin layer 1: Unifying panel on the underside HBF 40mm (20+20mm)

Insulation on supporting structure 343 kg/m2
Verified calculation ≈ 0.163 W/m2K
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF