LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0115

Lignum ID-№
F0115
Catalog number
F.1.05.DA645E
Source of construction assembly
Tschopp, Year 2017
Base structure
Ribs / rafters
Sheathing
without sheathing
Paneling
Simple covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
613 mm
Weight
261 kg/m2
U-value
≈ 0.115 W/m2K
GWP
179.60 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of ribs / rafters with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤50 kPa s/m². without sheathing, . Simple covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 57 dB
C -2 dB
Ctr -7 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Battens / profiles: Wood lath transversely b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 3 Garden plates Generic product 40 mm 96 kg/m2 - - 02.007 91.136
Use and protection layer 2 Gravel 8-16mm Generic product 40 mm 59.2 kg/m2 - - 03.011 91.062
Use and protection layer 1 Protective layer Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Exterior insulation layer 1 Thermal insulation material with compressive strength ≥50kPa according to EN 826 Gutex, Isover 60 mm 6.6 kg/m2 - - 10.009 91.051
Separating layer / temporary roof Vapor-permeable barrier Generic product 10 mm 3.9 kg/m2 - - 09.006 91.149
Sheathed above 2nd layer 3-layer panels Generic product 27 mm 13.2 kg/m2 - - 07.001 91.048
Bond no composite action - - - - - - -
Support Rib/bar Generic product, Label swiss wood 360 mm 22.6 kg/m2 80 mm 625 mm 07.003.01 91.047
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 360 mm 11.5 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Vapor barrier Moisture-adaptive vapor barrier Generic product 1 mm 1.5 kg/m2 - - 09.002 91.037
Battens / profiles Wood lath transversely b=60mm Generic product, Label swiss wood 30 mm 2.2 kg/m2 60 mm 400 mm 07.011 91.052
Covering below 1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface below Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
266153
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
169109
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
97155
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1224.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1199.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
657.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
541.60
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
25.00
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
503.70
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
502.40
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
257.80
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
244.10
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.30
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
720.40
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
696.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
399.60
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
297.40
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
23.70
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
179.60
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
94.30
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
85.40
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
78.47
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
21.40
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)