LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0123

Lignum ID-№
F0123
Catalog number
F.2.01.4303
Source of construction assembly
Lignatur, Year 2020
Base structure
Hollow box element
Sheathing
Sheathed left & rightside
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
537 mm
Weight
183 kg/m2
U-value
≈ 0.103 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Flat roof / shed roof consisting of a basic construction of hollow box element without cavity insulation in the supporting structure. Sheathed left & rightside, leftside single sheathed rightside single sheathed. Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 50 dB
C -2 dB
Ctr -6 dB
Values of footfall sound insulation
Ln,w 45 dB
CI -4 dB
CI50-2500 2 dB

Graphic

Use and protection layer 2: Garden plates
Use and protection layer 1: Props screw for hollow floor
Under the roof: Roofing underlay
Exterior insulation layer 1: ISOVER EPS insulation board DEO ie, DAA ie, DAD ie
Separating layer / temporary roof: Vapor barrier bituminous
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Lower skin layer 1: Lignatur surface element sheathing below

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 2 Garden plates Generic product 40 mm 96 kg/m2 - - 02.007 91.136
Use and protection layer 1 Props screw for hollow floor Knauf 46 mm - - - - -
Under the roof Roofing underlay Generic product 5 mm 2.3 kg/m2 - - 09.008 91.037
Exterior insulation layer 1 ISOVER EPS insulation board DEO ie, DAA ie, DAD ie Isover 202 mm 5.3 kg/m2 - - 10.004 91.151
Separating layer / temporary roof Vapor barrier bituminous Generic product 4 mm 4.4 kg/m2 - - 09.003 91.172
Sheathed above 1st layer Lignatur surface element sheathing above Lignatur 31 mm 14.6 kg/m2 - - 07.011.01 91.052
Support Lignatur surface element LFE Lignatur 178 mm 1.4 kg/m2 31 mm 242 mm 07.011.01 91.052
Dampening in supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 49 mm 59.8 kg/m2 - - 03.011 91.062
Lower skin layer 1 Lignatur surface element sheathing below Lignatur 31 mm - - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement 27 29 33 35 33 34 35 36 40 43 47 50 53 59 65 69 72 75 76 79 80
Calculation Lignum/Kühn and Blickle 14 16 19 22 24 27 29 28 31 33 36 39 41 44 44 44 45 53 62 69 78 86
Impact sound (Ln) Measurement 27 29 33 35 33 34 35 36 40 43 47 50 53 59 65 69 72 75 76 79 80
Calculation Lignum/Kühn and Blickle 67 68 68 68 69 69 70 74 75 75 75 75 76 76 79 82 84 78 73 69 63 57

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
0
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
0
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
0
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
0
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
0
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
0
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
0
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)