LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0127

Lignum ID-№
F0127
Catalog number
F.2.01.4295
Source of construction assembly
Lignatur, Year 2020
Base structure
Hollow box element
Sheathing
Sheathed left & rightside
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
499 mm
Weight
166 kg/m2
U-value
≈ 0.127 W/m2K
GWP
0.00 kg CO2-eq/m2
Type sound insulation
Measurement
Flat roof / shed roof consisting of a basic construction of hollow box element without cavity insulation in the supporting structure. Sheathed left & rightside, leftside single sheathed rightside single sheathed. Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 64 dB
C -2 dB
Ctr -6 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 2: Gravel 8-16mm
Under the roof: Roofing underlay
Exterior insulation layer 1: ISOVER EPS insulation board DEO ie, DAA ie, DAD ie
Separating layer / temporary roof: Vapor barrier bituminous
Sheathed above 1st layer: Lignatur surface element sheathing above
Support: Lignatur surface element LFE
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Lower skin layer 1: Lignatur surface element sheathing below

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 2 Gravel 8-16mm Generic product 50 mm 74 kg/m2 - - 03.011 91.062
Under the roof Roofing underlay Generic product 5 mm 2.3 kg/m2 - - 09.008 91.037
Exterior insulation layer 1 ISOVER EPS insulation board DEO ie, DAA ie, DAD ie Isover 200 mm 5.2 kg/m2 - - 10.004 91.151
Separating layer / temporary roof Vapor barrier bituminous Generic product 4 mm 4.4 kg/m2 - - 09.003 91.172
Sheathed above 1st layer Lignatur surface element sheathing above Lignatur 31 mm 14.6 kg/m2 - - 07.011.01 91.052
Support Lignatur surface element LFE Lignatur 178 mm 1.4 kg/m2 31 mm 242 mm 07.011.01 91.052
Dampening in supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 41 mm 50 kg/m2 - - 03.011 91.062
Lower skin layer 1 Lignatur surface element sheathing below Lignatur 31 mm 14.6 kg/m2 - - 07.011.01 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement 34 33 34 41 46 49 52 61 65 63 60 59 61 63 64 65 67 70 71 73 75
Calculation Lignum/Kühn and Blickle 13 15 18 21 23 26 28 27 30 33 35 38 41 43 43 43 44 53 61 68 77 86
Impact sound (Ln) Measurement 34 33 34 41 46 49 52 61 65 63 60 59 61 63 64 65 67 70 71 73 75
Calculation Lignum/Kühn and Blickle 68 69 69 69 70 70 71 75 75 75 76 76 76 77 80 83 85 79 74 70 64 58

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
0
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
0
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
0
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
0.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
0.00
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
0.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.00
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
0.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0.00
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
0.00
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
0.00
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
0.00
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
0.00
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0.00
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0.00
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)