Components

Construction assembly F0130

Lignum ID-№
F0130
Catalog number
F.2.01.FC4
Source of construction assembly
GAS 01-F01-04-de-01, Year 2019
Base structure
Hollow box element
Sheathing
Sheathed left & rightside
Paneling
Without covering
Reference fire protection
VKF Brandschutzanwendung Nr. 15421
Construction height
533 mm
Weight
343 kg/m2
U-value
≈ 0.163 W/m2K
GWP
75.10 kg CO2-eq/m2
Type sound insulation
Verified calculation
Flat roof / shed roof consisting of a basic construction of hollow box element without cavity insulation in the supporting structure. Sheathed left & rightside, leftside single sheathed rightside single sheathed. Without covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 62 dB
C dB
Ctr dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 3: Gravel [partially broken] 16-32mm
Use and protection layer 1: Concrete panels
Seal: Elastomerbitumen-Dichtungsbahn Sopravap EVA 35 flam
Exterior insulation layer 2: Expanded polystyrene (EPS)
Exterior insulation layer 1: Concrete panels
Separating layer / temporary roof: Crumb rubber mat
Sheathed above 1st layer: Querrost oben zu Block Lignotrend Q3 (b=65mm e=125mm)
Support: Block Lignotrend Q3
Lower skin layer 1: Unifying panel on the underside HBF 40mm (20+20mm)

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 3 Gravel [partially broken] 16-32mm Generic product 50 mm 84 kg/m2 - - 03.011 91.062
Use and protection layer 1 Concrete panels Generic product 40 mm 94.8 kg/m2 - - 02.007 91.136
Seal Elastomerbitumen-Dichtungsbahn Sopravap EVA 35 flam Generic product 2.5 mm 3.3 kg/m2 - - 09.003.12 91.172
Exterior insulation layer 2 Expanded polystyrene (EPS) Swisspor, Sager 200 mm 3 kg/m2 - - 10.004 91.151
Exterior insulation layer 1 Concrete panels Generic product 40 mm 94.8 kg/m2 - - 02.007 91.136
Separating layer / temporary roof Crumb rubber mat Generic product 5 mm 4.9 kg/m2 - - - -
Sheathed above 1st layer Querrost oben zu Block Lignotrend Q3 (b=65mm e=125mm) Lignotrend 45 mm 11.5 kg/m2 - - 07.011.01 91.052
Support Block Lignotrend Q3 Lignotrend 119 mm 31.2 kg/m2 71.7 mm 134 mm 07.003.01 91.047
Lower skin layer 1 Unifying panel on the underside HBF 40mm (20+20mm) Lignotrend 32 mm 15.7 kg/m2 - - 07.001 91.048

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 13 16 18 21 24 26 28 27 30 33 36 38 41 43 44 44 44 53 61 69 78 86
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 68 68 69 69 69 70 71 74 75 75 75 76 76 77 79 83 85 79 74 69 63 58

Airborne sound (R)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
129942
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
96612
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
33454
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
780.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
757.70
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
413.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
346.20
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
22.20
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
534.60
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
533.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
237.10
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
295.70
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.10
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
246.60
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
225.60
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
175.50
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
50.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
21.20
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
75.10
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
52.10
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
23.20
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
94.97
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
25.90
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)