Page 3 of 8. There were 157 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

D0910

Solid wood panel 275 mm 37 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 25 [MN/m³]
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Compact facade 95 kg/m2 -2 dB
Verified calculation ≈ 0.209 W/m2K -5 dB
Detail IFC4 LOD300

D0917

Solid wood panel 312 mm 42 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Ventilated facade 87 kg/m2 -1 dB
Verified calculation ≈ 0.21 W/m2K -7 dB
Detail IFC4 LOD300

D0928

Solid wood panel 290 mm 39 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 25 [MN/m³]
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Compact facade 111 kg/m2 -2 dB
Verified calculation ≈ 0.207 W/m2K -5 dB
Detail IFC4 LOD300

D0935

Solid wood panel 327 mm 43 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Ventilated facade 103 kg/m2 -1 dB
Verified calculation ≈ 0.208 W/m2K -6 dB
Detail IFC4 LOD300

D0954

Stud 335 mm 45 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 77 kg/m2 -3 dB
Calculation ≈ 0.189 W/m2K -8 dB
Detail IFC4 LOD300

D0955

Stud 375 mm 46 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 80 kg/m2 -3 dB
Calculation ≈ 0.167 W/m2K -8 dB
Detail IFC4 LOD300

D0956

Stud 395 mm 47 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 82 kg/m2 -3 dB
Calculation ≈ 0.157 W/m2K -8 dB
Detail IFC4 LOD300

D0957

Stud 475 mm 48 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 89 kg/m2 -3 dB
Calculation ≈ 0.128 W/m2K -8 dB
Detail IFC4 LOD300

D0958

Stud 535 mm 48 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 94 kg/m2 -3 dB
Calculation ≈ 0.112 W/m2K -8 dB
Detail IFC4 LOD300

D0959

Stud 316 mm 45 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Mineral wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 69 kg/m2 -3 dB
Calculation ≈ 0.171 W/m2K -8 dB
Detail IFC4 LOD300

D0960

Stud 356 mm 45 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Mineral wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 71 kg/m2 -3 dB
Calculation ≈ 0.147 W/m2K -8 dB
Detail IFC4 LOD300

D0961

Stud 376 mm 46 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Mineral wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 72 kg/m2 -3 dB
Calculation ≈ 0.138 W/m2K -8 dB
Detail IFC4 LOD300

D0962

Stud 456 mm 48 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Mineral wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 76 kg/m2 -3 dB
Calculation ≈ 0.109 W/m2K -8 dB
Detail IFC4 LOD300

D0963

Stud 516 mm 49 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Mineral wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Ventilated facade 79 kg/m2 -3 dB
Calculation ≈ 0.095 W/m2K -8 dB
Detail IFC4 LOD300

D0964

Stud 320 mm 46 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 78 kg/m2 -1 dB
Calculation ≈ 0.203 W/m2K -7 dB
Detail IFC4 LOD300

D0965

Stud 360 mm 46 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 82 kg/m2 -1 dB
Calculation ≈ 0.177 W/m2K -7 dB
Detail IFC4 LOD300

D0966

Stud 400 mm 48 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 85 kg/m2 -1 dB
Calculation ≈ 0.157 W/m2K -7 dB
Detail IFC4 LOD300

D0967

Stud 460 mm 49 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 90 kg/m2 -1 dB
Calculation ≈ 0.134 W/m2K -7 dB
Detail IFC4 LOD300

D0968

Stud 540 mm 49 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 96 kg/m2 -1 dB
Calculation ≈ 0.112 W/m2K -7 dB
Detail IFC4 LOD300

D0969

Stud 308 mm 47 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 80 kg/m2 -1 dB
Calculation ≈ 0.203 W/m2K -7 dB
Detail IFC4 LOD300