LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0969

Lignum ID-№
D0969
Catalog number
D.1.02.AW305A
Source of construction assembly
Tschopp, Year 2017
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Without substructure, directly sheathed
Construction height
307 mm
Weight
80 kg/m2
U-value
≈ 0.203 W/m2K
GWP
24.60 kg CO2-eq/m2
Type sound insulation
Calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering. Ventilated facade.
Values of airborne sound insulation
Rw 47 dB
C -1 dB
Ctr -7 dB

Graphic

Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer mineral, cement-based building board Generic product 8 mm 9.6 kg/m2 - - 03.003 91.137
Battens / profiles (ventilation) Wood lath transversely b=80mm Generic product, Label swiss wood 40 mm 3.8 kg/m2 80 mm 417 mm 07.011 91.052
Sheathed outside leftside 1st layer Wood fiber board ≥ 180kg/m³ Gutex, Isover 20 mm 3.6 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood 140 mm 4.6 kg/m2 40 mm 595 mm 07.003.01 91.047
Cavity dampening Cellulose: Loose; not monitored Generic product 140 mm 7 kg/m2 - - 10.010 91.046
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Bresta Solid timber panel Tschopp 87 mm 42.6 kg/m2 - - 07.011.02 91.052
Covering rightside1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
51226
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
44892
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6436
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
604.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
597.00
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
307.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
291.90
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.90
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
519.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
518.50
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
228.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
289.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.50
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
87.80
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
80.40
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
78.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
2.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
7.40
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
24.60
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
21.50
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.10
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
100.47
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
27.40
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)