LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0958

Lignum ID-№
D0958
Catalog number
D.1.02.AW100E
Source of construction assembly
Tschopp, Year 2017
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Without substructure, directly sheathed
Construction height
535 mm
Weight
94 kg/m2
U-value
≈ 0.112 W/m2K
GWP
22.50 kg CO2-eq/m2
Type sound insulation
Calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering. Ventilated facade.
Values of airborne sound insulation
Rw 48 dB
C -3 dB
Ctr -8 dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 20 mm 9.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=60mm Generic product, Label swiss wood 40 mm 1.9 kg/m2 60 mm 625 mm 07.011 91.052
Sheathed outside leftside 1st layer Wood fiber board ≥ 180kg/m³ Gutex, Isover 20 mm 3.6 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood 360 mm 11.9 kg/m2 40 mm 595 mm 07.003.01 91.047
Cavity dampening Cellulose: Loose; not monitored Generic product 360 mm 18 kg/m2 - - 10.010 91.046
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer OSB panel Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9.8 kg/m2 - - 07.013 91.145
Covering rightside1st layer Bresta Solid timber panel Tschopp 80 mm 39.2 kg/m2 - - 07.011.02 91.052

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
53244
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
44613
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
8630
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
749.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
738.70
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
337.60
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
402.50
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
10.60
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
655.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
654.90
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
260.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
394.30
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.70
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
95.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
85.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
77.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
8.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
9.90
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
22.50
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
17.70
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.90
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
148.87
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
40.60
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)