LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0960

Lignum ID-№
D0960
Catalog number
D.1.02.AW120B
Source of construction assembly
Tschopp, Year 2017
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Without substructure, directly sheathed
Construction height
355 mm
Weight
71 kg/m2
U-value
≈ 0.147 W/m2K
GWP
17.20 kg CO2-eq/m2
Type sound insulation
Calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering. Ventilated facade.
Values of airborne sound insulation
Rw 45 dB
C -3 dB
Ctr -8 dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Mineral wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: OSB panel
Covering rightside1st layer: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 20 mm 9.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 40 mm 1.9 kg/m2 60 mm 625 mm 07.011 91.052
Sheathed outside leftside 1st layer Vapor-permeable water barrier Generic product 0.5 mm 0.2 kg/m2 - - 09.006 91.149
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood 200 mm 6.6 kg/m2 40 mm 595 mm 07.003.01 91.047
Cavity dampening Mineral wool Generic product 200 mm 4 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer OSB panel Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9.8 kg/m2 - - 07.013 91.145
Covering rightside1st layer Bresta Solid timber panel Tschopp 80 mm 39.2 kg/m2 - - 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 8 10 12 14 15 14 20 25 33 40 46 53 59 66 71 77 82 88 94 100 109 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
41024.8
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
35792.1
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
5193
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
663.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
655.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
301.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
355.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
592.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
591.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
242
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
349.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
72.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
65.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
60.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
5.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
17.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
13.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
109.63333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
29.9
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)