LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0935

Lignum ID-№
D0935
Catalog number
D.3.01.N41
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Type of facade
Ventilated facade
Paneling
Without covering
Construction height
327 mm
Weight
103 kg/m2
U-value
≈ 0.208 W/m2K
GWP
43.10 kg CO2-eq/m2
Type sound insulation
Verified calculation
Outer wall consisting of a basic construction of solid timber without cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Without covering. Ventilated facade.
Values of airborne sound insulation
Rw 43 dB
C -1 dB
Ctr -6 dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 22 mm 10.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=50mm Generic product, Label swiss wood 30 mm 1.2 kg/m2 50 mm 625 mm 07.011 91.052
Sheathed outside leftside 2nd layer Wood fiber facade insulation board ≥ 180kg/m³ Gutex, Isover 160 mm 28.8 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 100 mm 47 kg/m2 1000 mm 1000 mm 07.002 91.047
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 23 25 28 31 33 36 38 37 34 36 33 36 39 41 41 41 42 51 59 66 76 84

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
90144.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
78426.2
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
11901.5
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
842.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
832.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
366.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
464.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
11.7
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
642.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
641.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
196.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
445.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.8
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
200.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
189.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
170.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
19.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
10.9
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
43.1
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
37.4
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
144.1
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
39.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)