Filter Catalog Outer wall

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 8 of 8. There were 157 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

D1194

BRESTA Solid Timber System 467 mm
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 2nd layer: Wood fiber board ≥ 180kg/m³
Sheathed outside leftside 1st layer: Schalung Nadelholz profiliert N+F
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel

Ventilated facade 143 kg/m2
Calculation without verification ≈ 0.155 W/m2K
Detail IFC4 LOD300

D1195

BRESTA Solid Timber System 547 mm
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 2nd layer: Wood fiber board ≥ 180kg/m³
Sheathed outside leftside 1st layer: Schalung Nadelholz profiliert N+F
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel

Ventilated facade 157 kg/m2
Calculation without verification ≈ 0.129 W/m2K
Detail IFC4 LOD300

D1196

BRESTA Solid Timber System 627 mm
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 2nd layer: Wood fiber board ≥ 180kg/m³
Sheathed outside leftside 1st layer: Schalung Nadelholz profiliert N+F
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel

Ventilated facade 171 kg/m2
Calculation without verification ≈ 0.11 W/m2K
Detail IFC4 LOD300

D1197

Solid timber, derived wood products 325 mm 65 dB
Sheathed outside leftside 1st layer: Rockwool ≥ 60kg/m³
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB
Coupling: Air
Battens / profiles: CD-ceiling profile b=60mm
Cavity dampening: Mineral Plus KP 034
Covering rightside1st layer: GKF/DF Knauf Piano
Covering rightside 2nd layer: GKF/DF Knauf Piano

Compact facade 98 kg/m2 -2 dB
Measurement ≈ 0.107 W/m2K -9 dB
Detail IFC4 LOD300

D1198

Solid timber, derived wood products 335 mm 65 dB
Surface 1: Mineral Basecoat, Knauf (Marmorit) SM 700
Sheathed outside leftside 1st layer: Rockwool ≥ 60kg/m³
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB
Coupling: Air
Battens / profiles: CD-ceiling profile b=60mm
Cavity dampening: Mineral Plus KP 034
Covering rightside1st layer: GKF/DF Knauf Piano
Covering rightside 2nd layer: GKF/DF Knauf Piano

Compact facade 98 kg/m2 -1 dB
Measurement ≈ 0.107 W/m2K -7 dB
Detail IFC4 LOD300

D1199

Solid timber, derived wood products 250 mm 40 dB
Surface 1: Mineral Basecoat, Knauf (Marmorit) SM 700
Sheathed outside leftside 1st layer: Rockwool ≥ 60kg/m³
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB

Compact facade 76 kg/m2 -2 dB
Measurement ≈ 0.157 W/m2K -4 dB
Detail IFC4 LOD300

D1200

Solid timber, derived wood products 260 mm 40 dB
Surface 1: Mineral Basecoat, Knauf (Marmorit) SM 700
Sheathed outside leftside 1st layer: Rockwool ≥ 60kg/m³
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB
Bond: Rigid, execution of the prior art.
Surface rightside: Mineral Basecoat, Knauf (Marmorit) SM 700

Compact facade 88 kg/m2 -2 dB
Measurement ≈ 0.157 W/m2K -5 dB
Detail IFC4 LOD300

D1201

Solid timber, derived wood products 110 mm 39 dB
Support: SWISS KRONO MAGNUMBOARD OSB
Bond: Rigid, execution of the prior art.
Surface rightside: Mineral Basecoat, Knauf (Marmorit) SM 700

Compact facade 78 kg/m2 -2 dB
Measurement ≈ 0.474 W/m2K -3 dB
Detail IFC4 LOD300

D1231

Stud 235 mm 45 dB
Surface 2: Deckputz
Surface 1: Mineral flush, GUTEX adhesive and spachtelputz/reinforcement fabric, GUTEX
Cover leftside 1st layer: GUTEX Thermoflex
Bond: no composite action
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Compact facade 48 kg/m2 -2 dB
Calculation without verification ≈ 0.163 W/m2K -7 dB
Detail IFC4 LOD300

D1232

Stud 235 mm 46 dB
Surface 2: Deckputz
Surface 1: Mineral flush, GUTEX adhesive and spachtelputz/reinforcement fabric, GUTEX
Cover leftside 1st layer: GUTEX Thermoflex
Bond: no composite action
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Compact facade 48 kg/m2 -3 dB
Calculation without verification ≈ 0.163 W/m2K -8 dB
Detail IFC4 LOD300

D1233

Stud 244 mm 46 dB
Cover leftside 1st layer: Duropal Xterior Compact F
Battens / profiles (ventilation): Wood lath b=60mm
Coupling: Facade membranes
Sheathed outside leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside leftside 1st layer: StyleBoard MDF.RWH
Bond: Stiff, execution of the prior art.
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Sheathed rightside 2nd layer: Plasterboard type A

Ventilated facade 72 kg/m2 -2 dB
Calculation without verification ≈ 0.196 W/m2K -7 dB
Detail IFC4 LOD300 (Missing File)

D1234

Stud 304 mm 46 dB
Surface 1: Duropal Xterior Compact F
Cover leftside 2nd layer: Facade membranes
Coupling: Aluminum profile facade substructure
Cavity dampening: Wood fiber facade insulation board ≥ 180kg/m³
Sheathed outside leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside leftside 1st layer: StyleBoard MDF.RWH
Bond: Stiff, execution of the prior art.
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Sheathed rightside 2nd layer: Plasterboard type A

Compact facade 81 kg/m2 -2 dB
Calculation without verification ≈ 0.163 W/m2K -7 dB
Detail IFC4 LOD300 (Missing File)

D1235

Stud 364 mm 46 dB
Surface 1: Duropal Xterior Compact F
Cover leftside 2nd layer: Facade membranes
Coupling: Aluminum profile facade substructure
Cavity dampening: Wood fiber facade insulation board ≥ 180kg/m³
Sheathed outside leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside leftside 1st layer: StyleBoard MDF.RWH
Bond: no composite action
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Wood fiber facade insulation board ≥ 180kg/m³
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Compact facade 99 kg/m2 -2 dB
Calculation without verification ≈ 0.134 W/m2K -7 dB
Detail IFC4 LOD300 (Missing File)

D1236

Stud 315 mm
Surface 2: Deckputz
Surface 1: Mineral flush, GUTEX adhesive and spachtelputz/reinforcement fabric, GUTEX
Cover leftside 1st layer: GUTEX Thermoflex
Bond: no composite action
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Wood fiber facade insulation board ≥ 180kg/m³
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Compact facade 63 kg/m2
Calculation without verification ≈ 0.126 W/m2K
Detail IFC4 LOD300 (Missing File)

D1237

Stud 304 mm 46 dB
Cover leftside 1st layer: Duropal Xterior Compact F
Battens / profiles (ventilation): Wood lath b=60mm
Coupling: Facade membranes
Sheathed outside leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside leftside 1st layer: StyleBoard MDF.RWH
Bond: no composite action
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Wood fiber facade insulation board ≥ 180kg/m³
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Ventilated facade 89 kg/m2 -2 dB
Calculation without verification ≈ 0.155 W/m2K -7 dB
Detail IFC4 LOD300 (Missing File)

D1247

Stud 243 mm 44 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Pavawall light
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Isocell
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: SWISS KRONO OSB/3

Compact facade 42 kg/m2 -3 dB
Measurement ≈ 0.158 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

D1248

Stud 256 mm 49 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Pavawall light
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Isocell
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: SWISS KRONO OSB/3
Sheathed rightside 2nd layer: GF-W2 Fermacell gypsum fiber board

Compact facade 56 kg/m2 -3 dB
Measurement ≈ 0.157 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)