D1194
|
BRESTA Solid Timber System |
467
mm
|
–
|
|
Ventilated facade |
143
kg/m2
|
–
|
Calculation without verification |
≈
0.155
W/m2K
|
–
|
Detail
IFC4 LOD300
|
D1195
|
BRESTA Solid Timber System |
547
mm
|
–
|
|
Ventilated facade |
157
kg/m2
|
–
|
Calculation without verification |
≈
0.129
W/m2K
|
–
|
Detail
IFC4 LOD300
|
D1196
|
BRESTA Solid Timber System |
627
mm
|
–
|
|
Ventilated facade |
171
kg/m2
|
–
|
Calculation without verification |
≈
0.11
W/m2K
|
–
|
Detail
IFC4 LOD300
|
D1197
|
Solid timber, derived wood products |
325
mm
|
65
dB
|
|
Compact facade |
98
kg/m2
|
-2
dB
|
Measurement |
≈
0.107
W/m2K
|
-9
dB
|
Detail
IFC4 LOD300
|
D1198
|
Solid timber, derived wood products |
335
mm
|
65
dB
|
|
Compact facade |
98
kg/m2
|
-1
dB
|
Measurement |
≈
0.107
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
D1199
|
Solid timber, derived wood products |
250
mm
|
40
dB
|
|
Compact facade |
76
kg/m2
|
-2
dB
|
Measurement |
≈
0.157
W/m2K
|
-4
dB
|
Detail
IFC4 LOD300
|
D1200
|
Solid timber, derived wood products |
260
mm
|
40
dB
|
|
Compact facade |
88
kg/m2
|
-2
dB
|
Measurement |
≈
0.157
W/m2K
|
-5
dB
|
Detail
IFC4 LOD300
|
D1201
|
Solid timber, derived wood products |
110
mm
|
39
dB
|
|
Compact facade |
78
kg/m2
|
-2
dB
|
Measurement |
≈
0.474
W/m2K
|
-3
dB
|
Detail
IFC4 LOD300
|
D1231
|
Stud |
235
mm
|
45
dB
|
|
Compact facade |
48
kg/m2
|
-2
dB
|
Calculation without verification |
≈
0.163
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
|
D1232
|
Stud |
235
mm
|
46
dB
|
|
Compact facade |
48
kg/m2
|
-3
dB
|
Calculation without verification |
≈
0.163
W/m2K
|
-8
dB
|
Detail
IFC4 LOD300
|
D1233
|
Stud |
244
mm
|
46
dB
|
|
Ventilated facade |
72
kg/m2
|
-2
dB
|
Calculation without verification |
≈
0.196
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
(Missing File)
|
D1234
|
Stud |
304
mm
|
46
dB
|
|
Compact facade |
81
kg/m2
|
-2
dB
|
Calculation without verification |
≈
0.163
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
(Missing File)
|
D1235
|
Stud |
364
mm
|
46
dB
|
|
Compact facade |
99
kg/m2
|
-2
dB
|
Calculation without verification |
≈
0.134
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
(Missing File)
|
D1236
|
Stud |
315
mm
|
–
|
|
Compact facade |
63
kg/m2
|
–
|
Calculation without verification |
≈
0.126
W/m2K
|
–
|
Detail
IFC4 LOD300
(Missing File)
|
D1237
|
Stud |
304
mm
|
46
dB
|
|
Ventilated facade |
89
kg/m2
|
-2
dB
|
Calculation without verification |
≈
0.155
W/m2K
|
-7
dB
|
Detail
IFC4 LOD300
(Missing File)
|
D1247
|
Stud |
243
mm
|
44
dB
|
|
Compact facade |
42
kg/m2
|
-3
dB
|
Measurement |
≈
0.158
W/m2K
|
-9
dB
|
Detail
IFC4 LOD300
(Missing File)
|
D1248
|
Stud |
256
mm
|
49
dB
|
|
Compact facade |
56
kg/m2
|
-3
dB
|
Measurement |
≈
0.157
W/m2K
|
-9
dB
|
Detail
IFC4 LOD300
(Missing File)
|