Components

Construction assembly D1200

Lignum ID-№
D1200
Catalog number
D.3.03.21001299/W10
Source of construction assembly
21-001299-PRO1 PB W10-F02-04-de-01, Year 2021
Base structure
Solid timber, derived wood products
Type of facade
Compact facade
Paneling
Without covering
Construction height
260 mm
Weight
88 kg/m2
U-value
≈ 0.157 W/m2K
GWP
45.70 kg CO2-eq/m2
Type sound insulation
Measurement
Outer wall consisting of a basic construction of solid timber, derived wood product without cavity insulation in the supporting structure. Sheathed outer side, on the outside single sheathed. Without covering. Compact facade.
Values of airborne sound insulation
Rw 40 dB
C -2 dB
Ctr -5 dB

Graphic

Surface 1: Mineral Basecoat, Knauf (Marmorit) SM 700
Sheathed outside leftside 1st layer: Rockwool ≥ 60kg/m³
Bond: Stiff, execution of the prior art.
Support: SWISS KRONO MAGNUMBOARD OSB
Bond: Rigid, execution of the prior art.
Surface rightside: Mineral Basecoat, Knauf (Marmorit) SM 700

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 1 Mineral Basecoat, Knauf (Marmorit) SM 700 Generic product 10 mm - - - - -
Sheathed outside leftside 1st layer Rockwool ≥ 60kg/m³ Generic product 140 mm 10.5 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145
Bond Rigid, execution of the prior art. - - - - - - -
Surface rightside Mineral Basecoat, Knauf (Marmorit) SM 700 Generic product 10 mm 12.3 kg/m2 - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 33 32 36 36 35 33 32 31 26 26 35 40 46 49 48 53 61 61 65 69 74
Calculation Lignum/Kühn and Blickle 22 24 26 29 30 29 30 36 38 45 46 53 59 66 71 77 82 88 95 101 109 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
82260
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
73872
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
8214
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
777.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
769.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
394.8
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
371.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
8.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
562.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
561.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
225.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
212.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
204.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
169.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
35.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
7.8
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
45.7
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
39.8
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.9
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
107.43333333333334
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
29.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)