Components

Construction assembly D1194

Lignum ID-№
D1194
Catalog number
D.3.01.AW185C
Source of construction assembly
Tschopp, Year 43378
Base structure
BRESTA Solid Timber System
Type of facade
Ventilated facade
Paneling
Without covering
Construction height
467 mm
Weight
143 kg/m2
U-value
≈ 0.155 W/m2K
GWP
42.40 kg CO2-eq/m2
Type sound insulation
Calculation without verification
Outer wall consisting of a basic construction of BRESTA Solid Timber System without cavity insulation in the supporting structure. Sheathed outer side, on the outside twice sheathed. Without covering. Ventilated facade.
Values of airborne sound insulation
Rw dB
C dB
Ctr dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 2nd layer: Wood fiber board ≥ 180kg/m³
Sheathed outside leftside 1st layer: Schalung Nadelholz profiliert N+F
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 20 mm 9.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 40 mm 1.9 kg/m2 60 mm 625 mm 07.011 91.052
Sheathed outside leftside 2nd layer Wood fiber board ≥ 180kg/m³ Gutex, Isover 220 mm 39.6 kg/m2 - - 10.009 91.051
Sheathed outside leftside 1st layer Schalung Nadelholz profiliert N+F Generic product, Origin mark Swiss wood 27 mm 13.5 kg/m2 - - 07.009 91.052
Bond Rigid, execution of the prior art. - - - - - - -
Support Bresta Solid timber panel Tschopp 160 mm 78.4 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 28 31 33 36 39 41 43 43 45 48 51 53 56 58 59 59 59 68 77 84 93 102

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
97325.9
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
82088.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
15504.5
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1370.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1356.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
594.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
764.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
16.3
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
1190.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
1189
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
445.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
743.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.1
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
185.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
170
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
149
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
21
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
15.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
42.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
34.7
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7.7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
231.36666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
63.1
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)