Components

Construction assembly D1232

Lignum ID-№
D1232
Catalog number
D.1.03.AW.60.HL_GF/GF
Source of construction assembly
Prüfbericht Nr. PB 2.3/20-370-1, Year 2022
Base structure
Stud
Type of facade
Compact facade
Paneling
Without covering
Construction height
234 mm
Weight
48 kg/m2
U-value
≈ 0.163 W/m2K
GWP
18.20 kg CO2-eq/m2
Type sound insulation
Calculation without verification
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed interior side, , roomside double sheathed. Without covering. Compact facade.
Values of airborne sound insulation
Rw 46 dB
C -3 dB
Ctr -8 dB

Graphic

Surface 2: Deckputz
Surface 1: Mineral flush, GUTEX adhesive and spachtelputz/reinforcement fabric, GUTEX
Cover leftside 1st layer: GUTEX Thermoflex
Bond: no composite action
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 2 Deckputz Fermacell, Knauf, Rigips 2 mm 2.7 kg/m2 - - - -
Surface 1 Mineral flush, GUTEX adhesive and spachtelputz/reinforcement fabric, GUTEX Gutex 5 mm 4.5 kg/m2 - - - -
Cover leftside 1st layer GUTEX Thermoflex Gutex 60 mm 3 kg/m2 - - 10.009 91.051
Bond no composite action - - - - - - -
Support Finger-jointed solid wood width = 60mm General Informations, Generic product, August Brühwiler, Dahinden Sägewerk, Filippi, Necker Holz, Schilliger Holz, Origin mark Swiss wood 140 mm 7.2 kg/m2 60 mm 571 mm 07.011 91.052
Cavity dampening Cellulose insulation CLIMACELL Catolet 140 mm 7.7 kg/m2 - - 10.010 91.046
Bond Rigid, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer LivingBoard P5 Pfleiderer 15 mm 10.5 kg/m2 - - 07.015 91.145
Sheathed rightside 2nd layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 12.5 mm 13.3 kg/m2 - - 03.007 91.063

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement MFPA Leipzig 25 23 29 26 24 27 28 38 40 39 42 46 49 53 55 60 64 60 60 65 67
Calculation Lignum/Kühn and Blickle 10 13 15 18 21 23 25 24 27 30 33 35 38 40 41 41 41 50 59 66 75 84

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
32172.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
27893.7
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
4292.2
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
192.6
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
188.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
90.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
97.5
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
4.5
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
110.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
109.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
22.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
87
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.3
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
82.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
78.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
67.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
10.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
4.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
18.2
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
16.1
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
44.366666666666670
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
12.1
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)