Filter Catalog Flat roof / shed roof

General Information

Consider the spectrum adaptation term:
Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 4 of 5. There were 100 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation Values of footfall sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

F0089

BRESTA Solid Timber System 729 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 423 kg/m2 -5 dB
Calculation ≈ 0.101 W/m2K -13 dB
Detail IFC4 LOD300

F0090

BRESTA Solid Timber System 769 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 424 kg/m2 -5 dB
Calculation ≈ 0.091 W/m2K -13 dB
Detail IFC4 LOD300

F0091

BRESTA Solid Timber System 829 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 425 kg/m2 -5 dB
Calculation ≈ 0.079 W/m2K -13 dB
Detail IFC4 LOD300

F0092

BRESTA Solid Timber System 909 mm 75 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation on supporting structure with covering 427 kg/m2 -5 dB
Calculation ≈ 0.067 W/m2K -13 dB
Detail IFC4 LOD300

F0093

Ribs / rafters 257 mm 45 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 55 kg/m2 -1 dB
Calculation ≈ 0.571 W/m2K -5 dB
Detail IFC4 LOD300

F0094

Ribs / rafters 277 mm 46 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 56 kg/m2 -1 dB
Calculation ≈ 0.566 W/m2K -5 dB
Detail IFC4 LOD300

F0095

Ribs / rafters 297 mm 47 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 58 kg/m2 -1 dB
Calculation ≈ 0.562 W/m2K -5 dB
Detail IFC4 LOD300

F0096

Ribs / rafters 317 mm 48 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 60 kg/m2 -1 dB
Calculation ≈ 0.557 W/m2K -5 dB
Detail IFC4 LOD300

F0097

Ribs / rafters 337 mm 49 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 61 kg/m2 -1 dB
Calculation ≈ 0.553 W/m2K -6 dB
Detail IFC4 LOD300

F0098

Ribs / rafters 357 mm 49 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 63 kg/m2 -1 dB
Calculation ≈ 0.549 W/m2K -5 dB
Detail IFC4 LOD300

F0099

Ribs / rafters 377 mm 50 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 64 kg/m2 -1 dB
Calculation ≈ 0.544 W/m2K -5 dB
Detail IFC4 LOD300

F0100

Ribs / rafters 357 mm 51 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar

Without insulation 66 kg/m2 -1 dB
Calculation ≈ 0.558 W/m2K -5 dB
Detail IFC4 LOD300

F0101

Ribs / rafters 375 mm 56 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between and on supporting structure with covering 232 kg/m2 -2 dB
Calculation ≈ 0.171 W/m2K -7 dB
Detail IFC4 LOD300

F0102

Ribs / rafters 415 mm 56 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between and on supporting structure with covering 236 kg/m2 -2 dB
Calculation ≈ 0.154 W/m2K -7 dB
Detail IFC4 LOD300

F0103

Ribs / rafters 455 mm 56 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between and on supporting structure with covering 240 kg/m2 -2 dB
Calculation ≈ 0.139 W/m2K -7 dB
Detail IFC4 LOD300

F0104

Ribs / rafters 535 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between and on supporting structure with covering 247 kg/m2 -2 dB
Calculation ≈ 0.118 W/m2K -7 dB
Detail IFC4 LOD300

F0105

Ribs / rafters 615 mm 57 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between and on supporting structure with covering 255 kg/m2 -2 dB
Calculation ≈ 0.102 W/m2K -7 dB
Detail IFC4 LOD300

F0106

Ribs / rafters 465 mm 57 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between the supporting structure of covering 87 kg/m2 -6 dB
Calculation ≈ 0.184 W/m2K -14 dB
Detail IFC4 LOD300

F0107

Ribs / rafters 505 mm 59 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between the supporting structure of covering 91 kg/m2 -5 dB
Calculation ≈ 0.164 W/m2K -13 dB
Detail IFC4 LOD300

F0108

Ribs / rafters 545 mm 61 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Insulation between the supporting structure of covering 94 kg/m2 -5 dB
Calculation ≈ 0.148 W/m2K -13 dB
Detail IFC4 LOD300