Components

Construction assembly F0091

Lignum ID-№
F0091
Catalog number
F.3.01.DA460D
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Sheathing
Sheathed on the leftside
Paneling
Double covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
829 mm
Weight
452 kg/m2
U-value
≈ 0.107 W/m2K
GWP
202.10 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of BRESTA Solid Timber System without cavity insulation in the supporting structure. Sheathed on the leftside, leftside single sheathed . Double covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 75 dB
C -5 dB
Ctr -13 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 1st layer: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Support: Bresta Solid timber panel
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 3 Solid timber b=80-150mm e=b+7mm Generic product 26 mm 13 kg/m2 - - 07.009 91.052
Use and protection layer 2 Wood lath b=40mm Generic product, Label swiss wood 60 mm 29.4 kg/m2 - - 07.011 91.052
Use and protection layer 1 Protective layer + Fire protection cover RF1 Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Exterior insulation layer 1 Thermal insulation material with compressive strength ≥50kPa according to EN 826 Gutex, Flumroc 300 mm 33 kg/m2 - - 10.009 91.051
Separating layer / temporary roof Vapor-permeable barrier Generic product 10 mm 3.9 kg/m2 - - 09.006 91.149
Sheathed above 1st layer Construction concrete, CEM II / A (cement content 290 kg/m³) Generic product 110 mm 260.7 kg/m2 - - 01.002 91.061
Bond Rigid, execution of the prior art. - - - - - - -
Support Bresta Solid timber panel Tschopp 110 mm 53.9 kg/m2 1000 mm 1000 mm 07.011.02 91.052
Bond no composite action - - - - - - -
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 125 mm - - 834 mm - -
Battens / profiles Wood lath transversely b=60mm Generic product, Label swiss wood 30 mm 2.2 kg/m2 60 mm 400 mm 07.011 91.052
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 80 mm 2.6 kg/m2 - - 10.008 91.173
Covering below 1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Covering below 2nd layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface below Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
314874
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
210454
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
104724
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1878.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1839.70
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
851.10
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
989.20
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
39.60
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
1102.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
1100.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
399.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
701.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
2.10
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
777.90
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
739.70
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
452.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
288.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
37.50
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
202.10
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
115.50
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
86.70
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
220.73
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
60.20
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)