LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0107

Lignum ID-№
F0107
Catalog number
F.1.03.DA630B
Source of construction assembly
Tschopp, Year 2017
Base structure
Ribs / rafters
Sheathing
without sheathing
Paneling
Simple covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
505 mm
Weight
91 kg/m2
U-value
≈ 0.164 W/m2K
GWP
171.90 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of ribs / rafters with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤50 kPa s/m². without sheathing, . Simple covering without insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 59 dB
C -5 dB
Ctr -13 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Wood lath transversely b=60mm
Under the roof: Roofing underlay
Sheathed above 2nd layer: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 2 Blowing clay Generic product 60 mm - - - 02.004 91.136
Use and protection layer 1 Protective layer Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Covering upside 1st layer Schalung Nadelholz profiliert N+F Generic product, Label swiss wood 27 mm 13.5 kg/m2 - - 07.009 91.052
Battens / profiles Wood lath transversely b=60mm Generic product, Label swiss wood 100 mm 4.7 kg/m2 60 mm 625 mm 07.011 91.052
Under the roof Roofing underlay Generic product 5 mm 2.3 kg/m2 - - 09.008 91.037
Sheathed above 2nd layer Thermal insulation material with compressive strength ≥50kPa according to EN 826 Gutex, Flumroc 35 mm 3.9 kg/m2 - - 10.009 91.051
Bond no composite action - - - - - - -
Support Rib/bar Generic product, Label swiss wood 220 mm 13.8 kg/m2 80 mm 625 mm 07.003.01 91.047
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 220 mm 7 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Vapor barrier Moisture-adaptive vapor barrier Generic product 1 mm 1.5 kg/m2 - - 09.002 91.037
Covering below 1st layer 3-layer panels Generic product 27 mm 13.2 kg/m2 - - 07.001 91.048

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
250259
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
152695
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
97588
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1423.10
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1403.70
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
609.20
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
794.30
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
19.10
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
704.30
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
703.00
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
230.50
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
471.80
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.10
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
719.10
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
700.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
378.70
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
322.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
18.00
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
171.90
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
81.40
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
90.50
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
151.07
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
41.20
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)