LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0104

Lignum ID-№
F0104
Catalog number
F.1.05.DA625D
Source of construction assembly
Tschopp, Year 2017
Base structure
Ribs / rafters
Sheathing
without sheathing
Paneling
Simple covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
535 mm
Weight
247 kg/m2
U-value
≈ 0.118 W/m2K
GWP
175.90 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of ribs / rafters with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². without sheathing, . Simple covering with insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 57 dB
C -2 dB
Ctr -7 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Sheathed above 2nd layer: 3-layer panels
Bond: no composite action
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Vapor barrier: Moisture-adaptive vapor barrier
Covering below 1st layer: 3-layer panels

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 3 Garden plates Generic product 40 mm 96 kg/m2 - - 02.007 91.136
Use and protection layer 2 Gravel 8-16mm Generic product 40 mm 59.2 kg/m2 - - 03.011 91.062
Use and protection layer 1 Protective layer Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Exterior insulation layer 1 Mineral wool Generic product 60 mm 1.2 kg/m2 - - 10.008 91.173
Separating layer / temporary roof Vapor-permeable barrier Generic product 10 mm 3.9 kg/m2 - - 09.006 91.149
Sheathed above 2nd layer 3-layer panels Generic product 27 mm 13.2 kg/m2 - - 07.001 91.048
Bond no composite action - - - - - - -
Support Rib/bar Generic product, Label swiss wood 300 mm 18.8 kg/m2 80 mm 625 mm 07.003.01 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 300 mm 9.6 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Vapor barrier Moisture-adaptive vapor barrier Generic product 1 mm 1.5 kg/m2 - - 09.002 91.037
Covering below 1st layer 3-layer panels Generic product 27 mm 13.2 kg/m2 - - 07.001 91.048

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 27 29 31 33 34 33 35 41 49 56 63 69 76 82 87 93 99 105 110 110 110 110
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 54 55 56 57 59 63 64 61 56 52 48 45 41 38 36 33 30 27 24 21 16 11

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
260206.8
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
164885.1
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
95411.8
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1290.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1266.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
724.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
543.1
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
23.6
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
587.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
586.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
340.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
244.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.2
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
703.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
681
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
383.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
298
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
22.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
175.9
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
91
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
85
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
78.46666666666665
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
21.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)