Filter Catalog Flat roof / shed roof

General Information

Consider the spectrum adaptation term:
Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 1 of 5. There were 100 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation Values of footfall sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

F0029

BRESTA Solid Timber System 170 mm 35 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 70 kg/m2 -1 dB
Calculation ≈ 0.485 W/m2K -3 dB
Detail IFC4 LOD300

F0030

BRESTA Solid Timber System 190 mm 35 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 80 kg/m2 -1 dB
Calculation ≈ 0.451 W/m2K -3 dB
Detail IFC4 LOD300

F0031

BRESTA Solid Timber System 210 mm 37 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 90 kg/m2 -1 dB
Calculation ≈ 0.422 W/m2K -3 dB
Detail IFC4 LOD300

F0032

BRESTA Solid Timber System 230 mm 37 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 99 kg/m2 -1 dB
Calculation ≈ 0.396 W/m2K -3 dB
Detail IFC4 LOD300

F0033

BRESTA Solid Timber System 250 mm 38 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 109 kg/m2 -1 dB
Calculation ≈ 0.374 W/m2K -3 dB
Detail IFC4 LOD300

F0034

BRESTA Solid Timber System 270 mm 39 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 119 kg/m2 -1 dB
Calculation ≈ 0.353 W/m2K -3 dB
Detail IFC4 LOD300

F0035

BRESTA Solid Timber System 290 mm 40 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 129 kg/m2 -1 dB
Calculation ≈ 0.335 W/m2K -3 dB
Detail IFC4 LOD300

F0036

BRESTA Solid Timber System 310 mm 40 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 139 kg/m2 -1 dB
Calculation ≈ 0.319 W/m2K -3 dB
Detail IFC4 LOD300

F0037

BRESTA Solid Timber System 330 mm 41 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Without insulation 148 kg/m2 -1 dB
Calculation ≈ 0.304 W/m2K -3 dB
Detail IFC4 LOD300

F0038

BRESTA Solid Timber System 547 mm 40 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Air
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Cellulose: Loose; not monitored
Separating layer / temporary roof: Vapor barrier bituminous
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 146 kg/m2 -1 dB
Calculation ≈ 0.17 W/m2K -7 dB
Detail IFC4 LOD300

F0039

BRESTA Solid Timber System 587 mm 41 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Air
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Cellulose: Loose; not monitored
Separating layer / temporary roof: Vapor barrier bituminous
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 148 kg/m2 -1 dB
Calculation ≈ 0.15 W/m2K -7 dB
Detail IFC4 LOD300

F0040

BRESTA Solid Timber System 627 mm 42 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Air
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Cellulose: Loose; not monitored
Separating layer / temporary roof: Vapor barrier bituminous
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 150 kg/m2 -1 dB
Calculation ≈ 0.134 W/m2K -7 dB
Detail IFC4 LOD300

F0041

BRESTA Solid Timber System 707 mm 42 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Air
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Cellulose: Loose; not monitored
Separating layer / temporary roof: Vapor barrier bituminous
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 154 kg/m2 -1 dB
Calculation ≈ 0.11 W/m2K -7 dB
Detail IFC4 LOD300

F0042

BRESTA Solid Timber System 767 mm 43 dB
Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Covering upside 1st layer: Schalung Nadelholz profiliert N+F
Battens / profiles: Air
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Cellulose: Loose; not monitored
Separating layer / temporary roof: Vapor barrier bituminous
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 157 kg/m2 -1 dB
Calculation ≈ 0.097 W/m2K -7 dB
Detail IFC4 LOD300

F0043

BRESTA Solid Timber System 446 mm 45 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 159 kg/m2 -2 dB
Calculation ≈ 0.133 W/m2K -6 dB
Detail IFC4 LOD300

F0044

BRESTA Solid Timber System 486 mm 45 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 159 kg/m2 -2 dB
Calculation ≈ 0.116 W/m2K -6 dB
Detail IFC4 LOD300

F0045

BRESTA Solid Timber System 506 mm 46 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 160 kg/m2 -2 dB
Calculation ≈ 0.109 W/m2K -6 dB
Detail IFC4 LOD300

F0046

BRESTA Solid Timber System 586 mm 46 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 161 kg/m2 -2 dB
Calculation ≈ 0.088 W/m2K -6 dB
Detail IFC4 LOD300

F0047

BRESTA Solid Timber System 646 mm 47 dB
Use and protection layer 3: Solid timber b=80-150mm e=b+7mm
Use and protection layer 2: Wood lath b=40mm
Use and protection layer 1: Protective layer + Fire protection cover RF1
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 163 kg/m2 -2 dB
Calculation ≈ 0.076 W/m2K -6 dB
Detail IFC4 LOD300

F0048

BRESTA Solid Timber System 440 mm 63 dB
Use and protection layer 3: Garden plates
Use and protection layer 2: Gravel 8-16mm
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Exterior insulation layer 1: Mineral wool
Separating layer / temporary roof: Vapor-permeable barrier
Bond: no composite action
Support: Bresta Solid timber panel

Insulation on supporting structure 271 kg/m2 -1 dB
Calculation ≈ 0.141 W/m2K -5 dB
Detail IFC4 LOD300