LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly F0033

Lignum ID-№
F0033
Catalog number
F.3.00.DA110E
Source of construction assembly
Tschopp, Year 2017
Base structure
BRESTA Solid Timber System
Sheathing
without sheathing
Paneling
Without covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
250 mm
Weight
109 kg/m2
U-value
≈ 0.374 W/m2K
GWP
133.60 kg CO2-eq/m2
Type sound insulation
Calculation
Flat roof / shed roof consisting of a basic construction of BRESTA Solid Timber System without cavity insulation in the supporting structure. without sheathing, . Without covering without insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 38 dB
C -1 dB
Ctr -3 dB
Values of footfall sound insulation
Ln,w dB
CI dB
CI50-2500 dB

Graphic

Use and protection layer 2: Blowing clay
Use and protection layer 1: Protective layer
Seal: Bituminous geomembrane
Bond: no composite action
Support: Bresta Solid timber panel

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Use and protection layer 2 Blowing clay Generic product 60 mm - - - 02.004 91.136
Use and protection layer 1 Protective layer Generic product 10 mm 9.2 kg/m2 - - 09.007 91.037
Seal Bituminous geomembrane Generic product 20 mm 22 kg/m2 - - 09.003 91.172
Bond no composite action - - - - - - -
Support Bresta Solid timber panel Tschopp 160 mm 78.4 kg/m2 1000 mm 1000 mm 07.011.02 91.052

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 27 29 32 35 37 40 42 41 44 47 49 52 55 57 58 57 58 67 75 83 92 100
Impact sound (Ln) Calculation Lignum/Kühn and Blickle 54 55 55 55 56 56 57 61 61 61 61 62 62 63 65 69 71 65 60 55 49 44

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
193168
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
108916.8
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
84243.4
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1329
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1312.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
625.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
690.1
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
15.6
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
796.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
795.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
375.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
419.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.9
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
535.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
520
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
250
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
270.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
14.7
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
133.6
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
54.7
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
78.9
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
129.79999999999998
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
35.4
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)