F0132
|
Hollow box element |
706
mm
|
49
dB
|
–
|
|
Insulation on supporting structure |
291
kg/m2
|
–
|
–
|
| Verified calculation |
≈
0.101
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0133
|
Ribs |
728
mm
|
55
dB
|
–
|
|
Insulation on supporting structure |
305
kg/m2
|
–
|
–
|
| Verified calculation |
≈
0.099
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0134
|
Hollow box element |
746
mm
|
55
dB
|
–
|
|
Insulation on supporting structure |
385
kg/m2
|
–
|
–
|
| Verified calculation |
≈
0.1
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0135
|
Hollow box element |
704
mm
|
53
dB
|
–
|
|
Insulation on supporting structure |
125
kg/m2
|
–
|
–
|
| Verified calculation |
≈
0.1
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0136
|
Hollow box element |
549
mm
|
62
dB
|
–
|
|
Insulation on supporting structure |
203
kg/m2
|
–
|
–
|
| Verified calculation |
≈
0.166
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0137
|
Ribs |
571
mm
|
60
dB
|
–
|
|
Insulation on supporting structure |
217
kg/m2
|
–
|
–
|
| Verified calculation |
≈
0.161
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0138
|
Hollow box element |
611
mm
|
62
dB
|
–
|
|
Insulation on supporting structure |
337
kg/m2
|
–
|
–
|
| Verified calculation |
≈
0.18
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0141
|
Ribs |
488
mm
|
45
dB
|
–
|
|
Insulation on supporting structure |
215
kg/m2
|
0
dB
|
–
|
| Verified calculation |
≈
0.126
W/m2K
|
3
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0142
|
Ribs |
468
mm
|
56
dB
|
–
|
|
Insulation on supporting structure |
180
kg/m2
|
-2
dB
|
–
|
| Verified calculation |
≈
0.166
W/m2K
|
-5
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0143
|
Ribs |
468
mm
|
64
dB
|
–
|
|
Insulation on supporting structure |
162
kg/m2
|
-2
dB
|
–
|
| Verified calculation |
≈
0.126
W/m2K
|
-6
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0144
|
Ribs |
468
mm
|
55
dB
|
–
|
|
Insulation on supporting structure |
163
kg/m2
|
-2
dB
|
–
|
| Verified calculation |
≈
0.126
W/m2K
|
-6
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0145
|
Ribs |
468
mm
|
64
dB
|
–
|
|
Insulation on supporting structure |
180
kg/m2
|
-2
dB
|
–
|
| Verified calculation |
≈
0.166
W/m2K
|
-6
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0146
|
Ribs |
346
mm
|
55
dB
|
44
dB
|
|
Insulation on supporting structure |
212
kg/m2
|
-2
dB
|
–
|
| Verified calculation |
≈
0.272
W/m2K
|
-7
dB
|
9
dB
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0147
|
Hollow box element |
399
mm
|
38
dB
|
54
dB
|
|
Insulation on supporting structure |
66
kg/m2
|
0
dB
|
1
dB
|
| Measurement |
≈
0.172
W/m2K
|
-3
dB
|
5
dB
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
|
F0148
|
Hollow box element |
444
mm
|
47
dB
|
54
dB
|
|
Insulation on supporting structure |
165
kg/m2
|
-2
dB
|
1
dB
|
| Measurement |
≈
0.171
W/m2K
|
-6
dB
|
3
dB
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0149
|
Ribs |
501
mm
|
51
dB
|
43
dB
|
|
Insulation on supporting structure |
277
kg/m2
|
-2
dB
|
-2
dB
|
| Measurement |
≈
0.131
W/m2K
|
-7
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0150
|
Ribs |
513
mm
|
51
dB
|
38
dB
|
|
Insulation on supporting structure |
277
kg/m2
|
-2
dB
|
-1
dB
|
| Measurement |
≈
0.131
W/m2K
|
-7
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0151
|
Ribs |
466
mm
|
–
|
–
|
|
Insulation on supporting structure |
180
kg/m2
|
–
|
–
|
| Measurement |
≈
0.166
W/m2K
|
–
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0152
|
Ribs |
431
mm
|
65
dB
|
46
dB
|
|
Insulation on supporting structure |
319
kg/m2
|
-3
dB
|
1
dB
|
| Measurement |
≈
0.119
W/m2K
|
-9
dB
|
7
dB
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|
F0153
|
Ribs |
491
mm
|
66
dB
|
44
dB
|
|
Insulation on supporting structure |
318
kg/m2
|
-3
dB
|
1
dB
|
| Measurement |
≈
0.165
W/m2K
|
-8
dB
|
–
|
|
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
|