LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch
Values of airborne sound insulation | |
---|---|
Rw | 62 dB |
C | dB |
Ctr | dB |
Values of footfall sound insulation | |
---|---|
Ln,w | dB |
CI | dB |
CI50-2500 | dB |
Layer | Product | Manufacturer | Thickness [mm] | Weight | Width (b) | Axial distance (e) | KBOB ID-№ Production | KBOB ID-№ Disposal |
---|---|---|---|---|---|---|---|---|
Use and protection layer 3 | Sheet made of aluminium strips with double standing seam | Generic product | 0.7 mm | 1.9 kg/m2 | - | - | 06.001 | 91.141 |
Seal | Bituminous geomembrane | Generic product | 4 mm | 4.4 kg/m2 | - | - | 09.003 | 91.172 |
Covering upside 1st layer | Parallel boards softwood, sawn surface | Generic product, Label swiss wood | 24 mm | 11.8 kg/m2 | - | - | 07.009 | 91.052 |
Battens / profiles | Wood lath b=80mm | Generic product, Label swiss wood | 80 mm | 5 kg/m2 | 80 mm | 625 mm | 07.011 | 91.052 |
Exterior insulation layer 2 | Rock wool | Generic product | 200 mm | 21.5 kg/m2 | - | - | 10.008 | 91.173 |
Exterior insulation layer 1 | Concrete panels | Generic product | 40 mm | 94.8 kg/m2 | - | - | 02.007 | 91.136 |
Separating layer / temporary roof | Crumb rubber mat | Generic product | 5 mm | 4.9 kg/m2 | - | - | - | - |
Sheathed above 1st layer | Querrost oben zu Block Lignotrend Q3 (b=65mm e=125mm) | Lignotrend | 45 mm | 11.5 kg/m2 | - | - | 07.011.01 | 91.052 |
Support | Block Lignotrend Q3 | Lignotrend | 119 mm | 31.2 kg/m2 | 71.7 mm | 134 mm | 07.003.01 | 91.047 |
Lower skin layer 1 | Unifying panel on the underside HBF 40mm (20+20mm) | Lignotrend | 32 mm | 15.7 kg/m2 | - | - | 07.001 | 91.048 |
Color | Type | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 4000 | 5000 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airborne sound (R) | Calculation | Lignum/Kühn and Blickle | 8 | 11 | 13 | 15 | 16 | 16 | 16 | 21 | 30 | 37 | 44 | 50 | 57 | 63 | 68 | 74 | 80 | 86 | 92 | 98 | 106 | 110 | ||
Impact sound (Ln) | Calculation | Lignum/Kühn and Blickle | 73 | 73 | 74 | 75 | 77 | 80 | 83 | 81 | 75 | 71 | 67 | 64 | 60 | 57 | 55 | 52 | 49 | 46 | 43 | 40 | 35 | 30 |
bSDD Properties | ||||||||
---|---|---|---|---|---|---|---|---|
mm | Indicators | Modules | ||||||
Values / m2 | ||||||||
+
|
Environmental impact points (UBP)
|
157017
|
UBP'21/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Environmental impact points from production (UBP_pro)
|
132299
|
UBP'21/m2
|
A1-A3
|
|||
|
┗
|
Environmental impact points from disposal (UBP_dis)
|
24740
|
UBP'21/m2
|
C1-C4
|
|||
+
|
Total primary energy (PE_T)
|
1178.40
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Primary energy from production (PE_pro)
|
1157.70
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Primary energy production, energetically consumed (PE_E_pro)
|
565.40
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Primary energy production, materially bound (PE_M_pro)
|
593.70
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Primary energy from disposal (PE_dis)
|
20.10
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Renewable primary energy (PE_RT)
|
871.10
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Renewable primary energy from production (PE_RT_pro)
|
869.80
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
|
315.90
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Renewable primary energy from production, materially bound (PE_RM_pro)
|
553.10
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Renewable primary energy from disposal (PE_RT_dis)
|
1.20
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Total use of non- renewable primary energy resources (PE_NRT)
|
308.20
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Primary energy not renewable from manufacturing (PE_NRT_pro)
|
289.40
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
|
249.30
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Primary energy not renewable from production, materially bound (PE_NRM_pro)
|
40.30
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Primary energy not renewable from disposal (PE_NRT_dis)
|
18.90
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Total greenhouse gas emissions (GWP_total)
|
80.00
|
kg CO2/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Greenhouse gas emissions from manufacturing (GWP_pro)
|
62.50
|
kg CO2/m2
|
A1-A3
|
|||
|
┗
|
Greenhouse gas emissions from waste disposal (GWP_dis)
|
17.60
|
kg CO2/m2
|
C1-C4
|
|||
|
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
|
177.47
|
kg CO2/m2
|
B1-B7
|
||||
|
Biogenic carbon storage (bio-C) (Not included in GWP)
|
48.40
|
kg C/m2
|
B1-B7
|
||||
⇒ Advantages of the life cycle assessment outside the system boundary (module D) |