Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

D1011

BRESTA Solid Timber System 380 mm 46 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 103 kg/m2 -1 dB
Calculation ≈ 0.175 W/m2K -7 dB
Detail IFC4 LOD300

D1012

BRESTA Solid Timber System 440 mm 48 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 113 kg/m2 -1 dB
Calculation ≈ 0.149 W/m2K -7 dB
Detail IFC4 LOD300

D1013

BRESTA Solid Timber System 480 mm 49 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 121 kg/m2 -1 dB
Calculation ≈ 0.135 W/m2K -7 dB
Detail IFC4 LOD300

D1014

Stud 320 mm 44 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: sheep wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 71 kg/m2 -1 dB
Calculation ≈ 0.203 W/m2K -7 dB
Detail IFC4 LOD300

D1015

Stud 360 mm 44 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: sheep wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 72 kg/m2 -1 dB
Calculation ≈ 0.177 W/m2K -7 dB
Detail IFC4 LOD300

D1016

Stud 380 mm 46 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: sheep wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 73 kg/m2 -1 dB
Calculation ≈ 0.166 W/m2K -7 dB
Detail IFC4 LOD300

D1017

Stud 440 mm 47 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: sheep wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 75 kg/m2 -1 dB
Calculation ≈ 0.14 W/m2K -7 dB
Detail IFC4 LOD300

D1018

Stud 520 mm 47 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: sheep wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 77 kg/m2 -1 dB
Calculation ≈ 0.117 W/m2K -7 dB
Detail IFC4 LOD300

D1019

BRESTA Solid Timber System 250 mm 39 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 67 kg/m2 -1 dB
Calculation ≈ 0.168 W/m2K -4 dB
Detail IFC4 LOD300

D1020

BRESTA Solid Timber System 270 mm 39 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 68 kg/m2 -1 dB
Calculation ≈ 0.153 W/m2K -4 dB
Detail IFC4 LOD300

D1021

BRESTA Solid Timber System 310 mm 40 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 69 kg/m2 -1 dB
Calculation ≈ 0.131 W/m2K -4 dB
Detail IFC4 LOD300

D1022

BRESTA Solid Timber System 350 mm 40 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 69 kg/m2 -1 dB
Calculation ≈ 0.114 W/m2K -4 dB
Detail IFC4 LOD300

D1023

BRESTA Solid Timber System 410 mm 41 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 71 kg/m2 -1 dB
Calculation ≈ 0.096 W/m2K -4 dB
Detail IFC4 LOD300

D1024

BRESTA Solid Timber System 263 mm 39 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 74 kg/m2 0 dB
Calculation ≈ 0.165 W/m2K -3 dB
Detail IFC4 LOD300

D1025

BRESTA Solid Timber System 283 mm 39 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 74 kg/m2 0 dB
Calculation ≈ 0.151 W/m2K -3 dB
Detail IFC4 LOD300

D1026

BRESTA Solid Timber System 303 mm 40 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 75 kg/m2 0 dB
Calculation ≈ 0.139 W/m2K -3 dB
Detail IFC4 LOD300

D1027

BRESTA Solid Timber System 363 mm 40 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 76 kg/m2 0 dB
Calculation ≈ 0.113 W/m2K -3 dB
Detail IFC4 LOD300

D1028

BRESTA Solid Timber System 423 mm 41 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 1st layer: Mineral wool
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 77 kg/m2 0 dB
Calculation ≈ 0.095 W/m2K -3 dB
Detail IFC4 LOD300

D1029

BRESTA Solid Timber System 270 mm 39 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Pavatherm
Sheathed outside leftside 1st layer: Diffutherm
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 90 kg/m2 -1 dB
Calculation ≈ 0.167 W/m2K -4 dB
Detail IFC4 LOD300

D1030

BRESTA Solid Timber System 310 mm 40 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Pavatherm
Sheathed outside leftside 1st layer: Diffutherm
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 97 kg/m2 -1 dB
Calculation ≈ 0.145 W/m2K -4 dB
Detail IFC4 LOD300