Components

Construction assembly D1014

Lignum ID-№
D1014
Catalog number
D.1.02.AW380A
Source of construction assembly
Tschopp, Year 2017
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Without substructure, directly sheathed
Construction height
319 mm
Weight
71 kg/m2
U-value
≈ 0.203 W/m2K
GWP
13.60 kg CO2-eq/m2
Type sound insulation
Calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering. Ventilated facade.
Values of airborne sound insulation
Rw 44 dB
C -1 dB
Ctr -7 dB

Graphic

Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: sheep wool
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Wood cladding horizontal, closed Generic product, VSH, Label swiss wood 20 mm 9.8 kg/m2 - - 07.009.01 91.052
Battens / profiles (ventilation) Wood lath transversely b=60mm Generic product, Origin mark Swiss wood 40 mm 1.9 kg/m2 60 mm 625 mm 07.011 91.052
Sheathed outside leftside 1st layer Wood fiber board ≥ 180kg/m³ Gutex, Isover 20 mm 3.6 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood 140 mm 4.3 kg/m2 40 mm 640 mm 07.003.01 91.047
Cavity dampening sheep wool Generic product 140 mm - - - - -
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Bresta Solid timber panel Tschopp 87 mm 42.6 kg/m2 - - 07.011.02 91.052
Covering rightside1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 12 14 16 19 20 21 20 21 31 38 45 52 59 65 70 76 82 88 94 100 108 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
34983.7
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
29801.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
5207.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
598.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
592.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
267.4
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
326.7
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.9
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
545.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
544.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
220.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
324.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
55.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
49.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
47
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
2.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
13.6
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
10.8
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
2.8
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
101.93333333333334
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
27.8
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)