Filter Catalog Steep roof

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 3 of 6. There were 117 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

E0160

BRESTA Solid Timber System 502 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Bond: Stiff, execution of the prior art.
Supporting structure: Bresta Solid timber panel

Insulation on supporting structure 133 kg/m2 -2 dB
Calculation ≈ 0.151 W/m2K -7 dB
Detail IFC4 LOD300

E0161

BRESTA Solid Timber System 562 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Bond: Stiff, execution of the prior art.
Supporting structure: Bresta Solid timber panel

Insulation on supporting structure 139 kg/m2 -2 dB
Calculation ≈ 0.131 W/m2K -7 dB
Detail IFC4 LOD300

E0162

Ribs / rafters 482 mm 41 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 88 kg/m2 -3 dB
Calculation ≈ 0.192 W/m2K -8 dB
Detail IFC4 LOD300

E0163

Ribs / rafters 522 mm 42 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 93 kg/m2 -3 dB
Calculation ≈ 0.164 W/m2K -8 dB
Detail IFC4 LOD300

E0164

Ribs / rafters 542 mm 43 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 96 kg/m2 -3 dB
Calculation ≈ 0.153 W/m2K -8 dB
Detail IFC4 LOD300

E0165

Ribs / rafters 602 mm 43 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 103 kg/m2 -3 dB
Calculation ≈ 0.127 W/m2K -8 dB
Detail IFC4 LOD300

E0166

Ribs / rafters 662 mm 44 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 110 kg/m2 -3 dB
Calculation ≈ 0.108 W/m2K -8 dB
Detail IFC4 LOD300

E0167

Ribs / rafters 504 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 91 kg/m2 -1 dB
Calculation ≈ 0.189 W/m2K -5 dB
Detail IFC4 LOD300

E0168

Ribs / rafters 544 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 96 kg/m2 -1 dB
Calculation ≈ 0.162 W/m2K -6 dB
Detail IFC4 LOD300

E0169

Ribs / rafters 584 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 100 kg/m2 -1 dB
Calculation ≈ 0.142 W/m2K -5 dB
Detail IFC4 LOD300

E0170

Ribs / rafters 644 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 108 kg/m2 -1 dB
Calculation ≈ 0.119 W/m2K -5 dB
Detail IFC4 LOD300

E0171

Ribs / rafters 704 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 115 kg/m2 -1 dB
Calculation ≈ 0.103 W/m2K -5 dB
Detail IFC4 LOD300

E0172

Ribs / rafters 502 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 89 kg/m2 -1 dB
Calculation ≈ 0.215 W/m2K -5 dB
Detail IFC4 LOD300

E0173

Ribs / rafters 542 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 93 kg/m2 -1 dB
Calculation ≈ 0.188 W/m2K -5 dB
Detail IFC4 LOD300

E0174

Ribs / rafters 562 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 96 kg/m2 -1 dB
Calculation ≈ 0.177 W/m2K -6 dB
Detail IFC4 LOD300

E0175

Ribs / rafters 622 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 102 kg/m2 -1 dB
Calculation ≈ 0.15 W/m2K -5 dB
Detail IFC4 LOD300

E0176

Ribs / rafters 682 mm 53 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 109 kg/m2 -1 dB
Calculation ≈ 0.131 W/m2K -5 dB
Detail IFC4 LOD300

E0177

Ribs / rafters 398 mm 49 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: OSB3 panel
Vapor barrier: Vapor barrier polyethylene (PE)
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 97 kg/m2 -5 dB
Calculation ≈ 0.198 W/m2K -11 dB
Detail IFC4 LOD300

E0178

Ribs / rafters 458 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: OSB3 panel
Vapor barrier: Vapor barrier polyethylene (PE)
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 105 kg/m2 -5 dB
Calculation ≈ 0.166 W/m2K -11 dB
Detail IFC4 LOD300

E0179

Ribs / rafters 498 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: OSB3 panel
Vapor barrier: Vapor barrier polyethylene (PE)
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Insulation between the supporting structure of covering 110 kg/m2 -5 dB
Calculation ≈ 0.15 W/m2K -11 dB
Detail IFC4 LOD300