LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly E0178

Lignum ID-№
E0178
Catalog number
E.1.03.DA920B
Source of construction assembly
Tschopp, Year 2017
Base structure
Ribs / rafters
Sheathing
Sheathed on both sides
Paneling
Simple covering
Reference fire protection
VKF 14-15, Kap. 3.3 / Lignum Doc. 2.1, Kap. 6
Construction height
457 mm
Weight
105 kg/m2
U-value
≈ 0.166 W/m2K
GWP
38.10 kg CO2-eq/m2
Type sound insulation
Calculation
Steep roof consisting of a basic construction of ribs / rafters with cavity insulation in the supporting structure. Sheathed left & rightside. Simple covering, without insulation on top of the sub-floor.
Values of airborne sound insulation
Rw 50 dB
C -5 dB
Ctr -11 dB

Comment Befestifung der Konterlattung mit Holzbauschraube HECO-Topix-T, 8 mmx400 mm mit Doppelgewinde; α = 90 °; a ≤ 750 mm

Graphic

Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: OSB3 panel
Vapor barrier: Vapor barrier polyethylene (PE)
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Surface below: Innenputz, verspachtelt

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Roofing Roof tiles Generic product 50 mm 42.7 kg/m2 - - 03.015 91.138
Battens / profiles Wood laths 48x48 + roof laths 48x24mm e=350mm Generic product, Label swiss wood 72 mm 2.8 kg/m2 50 mm 625 mm 07.009.01 91.052
Under the roof Roofing underlay Generic product 0.2 mm 0.1 kg/m2 - - 09.008 91.037
Sub-floor Thermal insulation material with compressive strength ≥50kPa according to EN 826 Gutex, Isover 35 mm 3.9 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 240 mm 18.8 kg/m2 100 mm 625 mm 07.003.01 91.047
Cavity dampening Cellulose: Loose; not monitored Generic product 240 mm 12 kg/m2 - - 10.010 91.046
Lower skin layer 1 OSB3 panel Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 15 mm 9.8 kg/m2 - - 07.013 91.145
Vapor barrier Vapor barrier polyethylene (PE) Generic product 0.3 mm 0.2 kg/m2 - - 09.002 91.037
Battens / profiles Wood lath b=60mm Generic product, Label swiss wood 30 mm 1.8 kg/m2 60 mm 500 mm 07.011 91.052
Covering below 1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface below Innenputz, verspachtelt Fermacell, Knauf, Rigips 3 mm 4.2 kg/m2 - - 04.001 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 19 21 23 25 26 25 27 33 41 48 55 62 68 74 80 86 91 97 103 109 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
65493.5
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
57088
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
8442.9
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
434.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
426
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
225.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
200.4
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
9.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
288.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
287.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
100
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
187.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.5
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
145.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
137.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
125
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
12.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
8.5
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
38.1
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
33.5
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.6
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
75.53333333333335
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
20.6
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)