Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

D0298

Stud 365 mm 61 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Ventilated facade 89 kg/m2 -5 dB
Verified calculation ≈ 0.161 W/m2K -12 dB
Detail IFC4 LOD300

D0447

Stud 296 mm 43 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: EPS or PUR with dynamic stiffness s' of ≤ 70 [MM / m²]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 57 kg/m2 -1 dB
Verified calculation ≈ 0.145 W/m2K -6 dB
Detail IFC4 LOD300

D0459

Stud 305 mm 48 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Mineral fiber, facade insulation s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 72 kg/m2 -2 dB
Verified calculation ≈ 0.15 W/m2K -7 dB
Detail IFC4 LOD300

D0461

Stud 320 mm 50 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Mineral fiber, facade insulation s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 88 kg/m2 -2 dB
Verified calculation ≈ 0.148 W/m2K -7 dB
Detail IFC4 LOD300

D0462

Stud 320 mm 48 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Mineral fiber, facade insulation s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Sheathed rightside 2nd layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 76 kg/m2 -1 dB
Verified calculation ≈ 0.147 W/m2K -6 dB
Detail IFC4 LOD300

D0463

Stud 305 mm 48 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 78 kg/m2 -2 dB
Verified calculation ≈ 0.169 W/m2K -6 dB
Detail IFC4 LOD300

D0464

Stud 309 mm 46 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³

Compact facade 73 kg/m2 -2 dB
Verified calculation ≈ 0.166 W/m2K -6 dB
Detail IFC4 LOD300

D0465

Stud 320 mm 50 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 94 kg/m2 -2 dB
Verified calculation ≈ 0.167 W/m2K -7 dB
Detail IFC4 LOD300

D0466

Stud 320 mm 48 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Sheathed rightside 2nd layer: Plasterboard type A
Surface rightside: Smoothed joints

Compact facade 82 kg/m2 -1 dB
Verified calculation ≈ 0.165 W/m2K -6 dB
Detail IFC4 LOD300

D0559

Stud 384 mm 51 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Mineral fiber, facade insulation s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 88 kg/m2 -2 dB
Verified calculation ≈ 0.119 W/m2K -7 dB
Detail IFC4 LOD300

D0560

Stud 384 mm 51 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 94 kg/m2 -2 dB
Verified calculation ≈ 0.132 W/m2K -7 dB
Detail IFC4 LOD300

D0601

Stud 380 mm 51 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Mineral fiber, facade insulation s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 93 kg/m2 -1 dB
Verified calculation ≈ 0.121 W/m2K -7 dB
Detail IFC4 LOD300

D0602

Stud 380 mm 52 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 99 kg/m2 -2 dB
Verified calculation ≈ 0.133 W/m2K -7 dB
Detail IFC4 LOD300

D0616

Stud 370 mm 61 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 97 kg/m2 -4 dB
Verified calculation ≈ 0.141 W/m2K -12 dB
Detail IFC4 LOD300

D0630

Stud 385 mm 64 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 113 kg/m2 -3 dB
Verified calculation ≈ 0.14 W/m2K -10 dB
Detail IFC4 LOD300

D0665

Stud 385 mm 62 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Sheathed rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 106 kg/m2 -4 dB
Verified calculation ≈ 0.139 W/m2K -11 dB
Detail IFC4 LOD300

D0733

Solid wood panel 350 mm 53 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 25 [MN/m³]
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 115 kg/m2 -2 dB
Verified calculation ≈ 0.163 W/m2K -7 dB
Detail IFC4 LOD300

D0737

Solid wood panel 387 mm 56 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Ventilated facade 107 kg/m2 -3 dB
Verified calculation ≈ 0.163 W/m2K -11 dB
Detail IFC4 LOD300

D0751

Solid wood panel 365 mm 58 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 25 [MN/m³]
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Compact facade 131 kg/m2 -3 dB
Verified calculation ≈ 0.161 W/m2K -8 dB
Detail IFC4 LOD300

D0755

Solid wood panel 402 mm 61 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=50mm
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath transversely b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Covering rightside1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering rightside 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface rightside: Glued joints/smoothed

Ventilated facade 123 kg/m2 -4 dB
Verified calculation ≈ 0.162 W/m2K -11 dB
Detail IFC4 LOD300