LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0464

Lignum ID-№
D0464
Catalog number
D.1.03.U42
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Type of facade
Compact facade
Paneling
Without covering
Construction height
309 mm
Weight
73 kg/m2
U-value
≈ 0.166 W/m2K
GWP
51.80 kg CO2-eq/m2
Type sound insulation
Verified calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤35 kPa s/m². Sheathed outside & interior, on the outside twice sheathed, roomside single sheathed. Without covering. Compact facade.
Values of airborne sound insulation
Rw 46 dB
C -2 dB
Ctr -6 dB

Graphic

Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Sheathed outside leftside 2nd layer: Wood fiber facade insulation board s' ≤ 50 [MN/m³]
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 1 Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish Generic product 15 mm 20 kg/m2 - - 04.011 91.139
Sheathed outside leftside 2nd layer Wood fiber facade insulation board s' ≤ 50 [MN/m³] Gutex, Isover 60 mm 10.8 kg/m2 - - 10.009 91.051
Sheathed outside leftside 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Origin mark Swiss wood 200 mm 9.4 kg/m2 60 mm 625 mm 07.002 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 200 mm 6.4 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Wood panel for structural purposes ≥ 600 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer 19 mm 11.4 kg/m2 - - 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 16 18 21 24 26 29 31 30 33 36 38 41 44 46 46 46 47 56 64 71 81 89

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
92687.1
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
85738.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
7018.5
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
509.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
503.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
328.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
174.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
7.1
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
263
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
262.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
100.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
161.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
247.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
240.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
227.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
12.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6.7
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
51.8
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
48.6
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.3
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
53.9
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
14.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)