Page 1 of 2. There were 21 matching products found.
Sia-№ Material group (according to SIA) Mittlere Rohdichte ρ Thickness [mm] Valid until
Product description Thermal conductivity Thermal conductivity (dry) Mortar
Manufacturer Heat capacity Vapour barrier value (dry) Vapour barrier value (damp)

20.01

Mauerwerk unverputzt 1100 kg/m3

Modulbackstein 0.44 W/mK 0.44 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020)

20.02

Mauerwerk unverputzt 1100 kg/m3

Verband Modulbackstein; deklariert 0.37 W/mK 0.37 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020)

20.03

Mauerwerk unverputzt 800 kg/m3

Leichtbackstein 780-850 kg/m3, deklariert 0.12 W/mK 0.12 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.04

Mauerwerk unverputzt 700 kg/m3

Leichtbackstein 680-750 kg/m3, deklariert 0.11 W/mK 0.11 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.05

Mauerwerk unverputzt 650 kg/m3

Leichtbackstein 620-680 kg/m3; deklariert 0.1 W/mK 0.1 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.06

Mauerwerk unverputzt 1200 kg/m3

Verband Leichtbackstein (Optitherm) 0.165 W/mK 0.165 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.07

Mauerwerk unverputzt 1150 kg/m3

Verband Leichtbackstein (Optitop) 0.12 W/mK 0.12 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.08

Mauerwerk unverputzt 1200 kg/m3

Isolierbackstein; deklariert 0.47 W/mK 0.47 W/mK
0.278 Wh / kgK 6 4
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.09

Mauerwerk unverputzt 1400 kg/m3

Sichtbackstein; deklariert 0.52 W/mK 0.52 W/mK
0.278 Wh / kgK 8 6
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.1

Mauerwerk unverputzt 1800 kg/m3

Klinker, deklariert 1.8 W/mK 1.8 W/mK
0.278 Wh / kgK 100
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.11

Mauerwerk unverputzt 1800 kg/m3

Vollbackstein 0.8 W/mK 0.8 W/mK
0.278 Wh / kgK 10 8
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.12

Mauerwerk unverputzt 1800 kg/m3

Kaminstein 0.8 W/mK 0.8 W/mK
0.278 Wh / kgK 10 8
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.13

Mauerwerk unverputzt 1600 kg/m3

Kalksandstein 1600 kg/m3 0.8 W/mK 0.8 W/mK
0.278 Wh / kgK 25 10
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.14

Mauerwerk unverputzt 1800 kg/m3

Kalksandstein 1800 kg/m3 1 W/mK 1 W/mK
0.278 Wh / kgK 25 10
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.15

Mauerwerk unverputzt 2000 kg/m3

Kalksandstein 2000 kg/m3 1.1 W/mK 1.1 W/mK
0.278 Wh / kgK 25 10
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.16

Mauerwerk unverputzt 2000 kg/m3

Zementstein 1.1 W/mK 1.1 W/mK
0.278 Wh / kgK 15 10
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.17

Mauerwerk unverputzt 1200 kg/m3

Zementblockstein 0.7 W/mK 0.7 W/mK
0.278 Wh / kgK 15 10
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.18

Mauerwerk unverputzt 300 kg/m3

Porenbetonstein 300 kg/m3 0.1 W/mK 0.1 W/mK
0.278 Wh / kgK 10 5
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.19

Mauerwerk unverputzt 400 kg/m3

Porenbetonstein 400 kg/m3 0.13 W/mK 0.13 W/mK
0.278 Wh / kgK 10 5
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].

20.2

Mauerwerk unverputzt 500 kg/m3

Porenbetonstein 500 kg/m3 0.16 W/mK 0.16 W/mK
0.278 Wh / kgK 10 5
Detail SN EN 1745 (2020) SN EN 12524 (2000) [archived].