LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

Printversion

Oekobilanzdaten

Innentüre, Aluminium, Glaseinsatz

Details

Category Türen
KBOB ID-№ Production 12.007
UUID number 70161147-1156-4B2D-B954-D6592929A8EF
KBOB ID-№ Disposal 91.165
Designation Disposal Entsorgung, Innentüre, Aluminium, Glaseinsatz
Declared unit m2
Last Update 16.12.2024

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
316000
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
305000
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
10500
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
827
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
823
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
823
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
3.94
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
104
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
104
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
104
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
0
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.339
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
722
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
719
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
719
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
0
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
3.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
166
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
157
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
8.710
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
0
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)