Filter Catalog Steep roof

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 1 of 6. There were 117 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

E0174

Ribs / rafters 562 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 96 kg/m2 -1 dB
Calculation ≈ 0.177 W/m2K -6 dB
Detail IFC4 LOD300

E0166

Ribs / rafters 662 mm 44 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 110 kg/m2 -3 dB
Calculation ≈ 0.108 W/m2K -8 dB
Detail IFC4 LOD300

E0130

Ribs / rafters 489 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering below 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between and on supporting structure with covering 103 kg/m2 -3 dB
Verified calculation ≈ 0.13 W/m2K -9 dB
Detail IFC4 LOD300

E0164

Ribs / rafters 542 mm 43 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 96 kg/m2 -3 dB
Calculation ≈ 0.153 W/m2K -8 dB
Detail IFC4 LOD300

E0232

Ribs / rafters 563 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Isorigid
Exterior insulation layer 1: ISOVER PB M 030
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Covering below 1st layer: Wood panel for structural purposes ≥ 450 kg/m³
Covering below 2nd layer: Rib/bar b=100mm

Insulation between and on supporting structure with covering 176 kg/m2 -3 dB
Calculation ≈ 0.127 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0169

Ribs / rafters 584 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 100 kg/m2 -1 dB
Calculation ≈ 0.142 W/m2K -5 dB
Detail IFC4 LOD300

E0135

Solid wood panel 419 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Insulation on supporting structure 112 kg/m2 -2 dB
Verified calculation ≈ 0.182 W/m2K -7 dB
Detail IFC4 LOD300

E0212

Ribs / rafters 395 mm 47 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 82 kg/m2 -3 dB
Calculation ≈ 0.119 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0199

Ribs / rafters 365 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A

Insulation between the supporting structure of covering 80 kg/m2 -3 dB
Calculation ≈ 0.161 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0160

BRESTA Solid Timber System 502 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Bond: Stiff, execution of the prior art.
Supporting structure: Bresta Solid timber panel

Insulation on supporting structure 133 kg/m2 -2 dB
Calculation ≈ 0.151 W/m2K -7 dB
Detail IFC4 LOD300

E0208

Ribs / rafters 457 mm 56 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 96 kg/m2 -3 dB
Calculation ≈ 0.132 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0195

Ribs / rafters 405 mm 45 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 81 kg/m2 -3 dB
Calculation ≈ 0.141 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0197

Ribs / rafters 445 mm 45 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 86 kg/m2 -3 dB
Calculation ≈ 0.125 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0203

Ribs / rafters 445 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A

Insulation between the supporting structure of covering 89 kg/m2 -3 dB
Calculation ≈ 0.126 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0211

Ribs / rafters 375 mm 47 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 80 kg/m2 -3 dB
Calculation ≈ 0.125 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0161

BRESTA Solid Timber System 562 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Bond: Stiff, execution of the prior art.
Supporting structure: Bresta Solid timber panel

Insulation on supporting structure 139 kg/m2 -2 dB
Calculation ≈ 0.131 W/m2K -7 dB
Detail IFC4 LOD300

E0209

Ribs / rafters 477 mm 56 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 98 kg/m2 -3 dB
Calculation ≈ 0.125 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0094

Ribs / rafters 436 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between and on supporting structure with covering 83 kg/m2 -4 dB
Verified calculation ≈ 0.143 W/m2K -11 dB
Detail IFC4 LOD300

E0147

BRESTA Solid Timber System, planked on one side 397 mm 36 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Lower skin layer 1: Vapor barrier polyethylene (PE)
Lower skin 2nd layer: Bresta Solid timber panel

Insulation between the supporting structure 106 kg/m2 -1 dB
Calculation ≈ 0.191 W/m2K -7 dB
Detail IFC4 LOD300

E0165

Ribs / rafters 602 mm 43 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Vapor barrier polyethylene (PE)
Sub-floor: Boards with blunt edges
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 103 kg/m2 -3 dB
Calculation ≈ 0.127 W/m2K -8 dB
Detail IFC4 LOD300