Filter Catalog Steep roof

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 1 of 6. There were 117 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

E0055

Ribs / rafters 504 mm 46 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 83 kg/m2 -3 dB
Verified calculation ≈ 0.19 W/m2K -9 dB
Detail IFC4 LOD300

E0056

Ribs / rafters 504 mm 46 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 81 kg/m2 -3 dB
Verified calculation ≈ 0.229 W/m2K -9 dB
Detail IFC4 LOD300

E0057

Ribs / rafters 584 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 90 kg/m2 -3 dB
Verified calculation ≈ 0.175 W/m2K -9 dB
Detail IFC4 LOD300

E0062

Ribs / rafters 519 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Mineral wool ≥ 15kPa (EN 826)
Sheathed above 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 99 kg/m2 -2 dB
Verified calculation ≈ 0.188 W/m2K -8 dB
Detail IFC4 LOD300

E0063

Ribs / rafters 519 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 97 kg/m2 -2 dB
Verified calculation ≈ 0.226 W/m2K -8 dB
Detail IFC4 LOD300

E0064

Ribs / rafters 599 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Sheathed above 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Sub-floor: Wood panel for structural purposes ≥ 450 kg/m³
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar

Insulation on supporting structure 106 kg/m2 -2 dB
Verified calculation ≈ 0.174 W/m2K -8 dB
Detail IFC4 LOD300

E0066

Ribs / rafters 408 mm 47 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Lower skin layer 1: Wood panel for structural purposes ≥ 450 kg/m³

Insulation between and on supporting structure 77 kg/m2 -3 dB
Verified calculation ≈ 0.164 W/m2K -11 dB
Detail IFC4 LOD300

E0070

Ribs / rafters 411 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Lower skin layer 1: OSB panel
Lower skin 2nd layer: Plasterboard type A
Surface below: Smoothed joints

Insulation between and on supporting structure 85 kg/m2 -3 dB
Verified calculation ≈ 0.164 W/m2K -10 dB
Detail IFC4 LOD300

E0073

Ribs / rafters 414 mm 47 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Plasterboard type A
Surface below: Smoothed joints

Insulation between the supporting structure of covering 75 kg/m2 -4 dB
Calculation without verification ≈ 0.15 W/m2K -12 dB
Detail IFC4 LOD300

E0077

Ribs / rafters 414 mm 49 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between the supporting structure of covering 80 kg/m2 -4 dB
Verified calculation ≈ 0.151 W/m2K -11 dB
Detail IFC4 LOD300

E0081

Ribs / rafters 429 mm 49 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Smoothed joints

Insulation between the supporting structure of covering 86 kg/m2 -3 dB
Verified calculation ≈ 0.149 W/m2K -10 dB
Detail IFC4 LOD300

E0085

Ribs / rafters 429 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering below 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between the supporting structure of covering 96 kg/m2 -3 dB
Verified calculation ≈ 0.149 W/m2K -10 dB
Detail IFC4 LOD300

E0090

Ribs / rafters 436 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Plasterboard type A
Surface below: Smoothed joints

Insulation between and on supporting structure with covering 78 kg/m2 -3 dB
Verified calculation ≈ 0.142 W/m2K -11 dB
Detail IFC4 LOD300

E0094

Ribs / rafters 436 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between and on supporting structure with covering 83 kg/m2 -4 dB
Verified calculation ≈ 0.143 W/m2K -11 dB
Detail IFC4 LOD300

E0098

Ribs / rafters 451 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Smoothed joints

Insulation between and on supporting structure with covering 89 kg/m2 -3 dB
Verified calculation ≈ 0.141 W/m2K -10 dB
Detail IFC4 LOD300

E0102

Ribs / rafters 451 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Covering below 2nd layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between and on supporting structure with covering 99 kg/m2 -4 dB
Verified calculation ≈ 0.142 W/m2K -10 dB
Detail IFC4 LOD300

E0105

Ribs / rafters 446 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Lower skin layer 1: Wood panel for structural purposes ≥ 450 kg/m³

Insulation between and on supporting structure 81 kg/m2 -4 dB
Verified calculation ≈ 0.148 W/m2K -11 dB
Detail IFC4 LOD300

E0110

Ribs / rafters 449 mm 49 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Lower skin layer 1: OSB panel
Lower skin 2nd layer: Plasterboard type A
Surface below: Glued joints/smoothed

Insulation between and on supporting structure 89 kg/m2 -3 dB
Verified calculation ≈ 0.149 W/m2K -10 dB
Detail IFC4 LOD300

E0115

Ribs / rafters 474 mm 49 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Plasterboard type A
Surface below: Smoothed joints

Insulation between and on supporting structure with covering 82 kg/m2 -4 dB
Verified calculation ≈ 0.131 W/m2K -11 dB
Detail IFC4 LOD300

E0120

Ribs / rafters 474 mm 51 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 1: Thermal insulation material with compressive strength ≥50kPa according to EN 826
Bond: no composite action
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Cavity dampening: Mineral wool
Covering below 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface below: Glued joints/smoothed

Insulation between and on supporting structure with covering 87 kg/m2 -4 dB
Verified calculation ≈ 0.131 W/m2K -11 dB
Detail IFC4 LOD300