Filter Catalog Partition wall single shell

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 6 of 6. There were 107 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

C0478

Solid wood panel 61 dB

with wallcovering 82 kg/m2 -4 dB
Measurement ≈ 0.339 W/m2K
Detail IFC4 LOD300 XLSX Test report PDF

C0479

Solid wood panel 68 dB

with wallcovering 114 kg/m2 -4 dB
Measurement ≈ 0.224 W/m2K
Detail IFC4 LOD300 XLSX Test report PDF

C0480

Solid wood panel 61 dB

with wallcovering 98 kg/m2
Verified calculation ≈ 0.318 W/m2K
Detail IFC4 LOD300 XLSX Test report PDF

C0481

Solid wood panel 68 dB

with wallcovering 131 kg/m2
Verified calculation ≈ 0.215 W/m2K
Detail IFC4 LOD300 XLSX Test report PDF

C0493

Solid wood panel 38 dB

Without wallcovering 66 kg/m2 -1 dB
Measurement ≈ 0.476 W/m2K
Detail IFC4 LOD300 XLSX Test report PDF

C0494

Solid wood panel 44 dB

Without wallcovering 94 kg/m2 -1 dB
Measurement ≈ 0.446 W/m2K
Detail IFC4 LOD300 XLSX Test report PDF

C0498

Stud 48 dB

Without wallcovering 46 kg/m2 -3 dB
Measurement ≈ 0.528 W/m2K
Detail IFC4 LOD300 XLSX Test report PDF