Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

E0220

Ribs / rafters 520 mm 60 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure of covering 104 kg/m2 -3 dB
Calculation ≈ 0.113 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0221

Ribs / rafters 600 mm 61 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure of covering 109 kg/m2 -3 dB
Calculation ≈ 0.102 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0222

Ribs / rafters 366 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sheathed above 1st layer: Isorigid
Sub-floor: Vario KM Supraplex-SKS
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 76 kg/m2 -2 dB
Calculation ≈ 0.16 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0223

Ribs / rafters 296 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sheathed above 1st layer: Isorigid
Sub-floor: Vario KM Supraplex-SKS
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 68 kg/m2 -2 dB
Calculation ≈ 0.227 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0224

Ribs / rafters 406 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sheathed above 1st layer: Isorigid
Sub-floor: Vario KM Supraplex-SKS
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 81 kg/m2 -2 dB
Calculation ≈ 0.139 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0225

Ribs / rafters 346 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 75 kg/m2 -2 dB
Calculation ≈ 0.172 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0226

Ribs / rafters 366 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 77 kg/m2 -2 dB
Calculation ≈ 0.157 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0227

Ribs / rafters 366 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 77 kg/m2 -2 dB
Calculation ≈ 0.16 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0228

Ribs / rafters 386 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 79 kg/m2 -2 dB
Calculation ≈ 0.147 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0229

Ribs / rafters 386 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 79 kg/m2 -2 dB
Calculation ≈ 0.15 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0230

Ribs / rafters 406 mm 52 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Battens / profiles: Wood lath b=60mm
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 82 kg/m2 -2 dB
Calculation ≈ 0.138 W/m2K -8 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0231

Ribs / rafters 543 mm 44 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Isorigid
Exterior insulation layer 1: ISOVER PB M 030
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Covering below 1st layer: Wood panel for structural purposes ≥ 450 kg/m³
Covering below 2nd layer: Rib/bar

Insulation between and on supporting structure with covering 176 kg/m2 -3 dB
Calculation ≈ 0.139 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0232

Ribs / rafters 563 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Isorigid
Exterior insulation layer 1: ISOVER PB M 030
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Covering below 1st layer: Wood panel for structural purposes ≥ 450 kg/m³
Covering below 2nd layer: Rib/bar

Insulation between and on supporting structure with covering 176 kg/m2 -3 dB
Calculation ≈ 0.127 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0233

Ribs / rafters 583 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Isorigid
Exterior insulation layer 1: ISOVER PB M 030
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Covering below 1st layer: Wood panel for structural purposes ≥ 450 kg/m³
Covering below 2nd layer: Rib/bar

Insulation between and on supporting structure with covering 178 kg/m2 -3 dB
Calculation ≈ 0.119 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0234

Ribs / rafters 603 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Isorigid
Exterior insulation layer 1: ISOVER PB M 030
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Covering below 1st layer: Wood panel for structural purposes ≥ 450 kg/m³
Covering below 2nd layer: Rib/bar

Insulation between and on supporting structure with covering 178 kg/m2 -3 dB
Calculation ≈ 0.11 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0235

Ribs / rafters 623 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Isorigid
Exterior insulation layer 1: ISOVER PB M 030
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Covering below 1st layer: Wood panel for structural purposes ≥ 450 kg/m³
Covering below 2nd layer: Rib/bar

Insulation between and on supporting structure with covering 180 kg/m2 -3 dB
Calculation ≈ 0.103 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF

E0236

Ribs / rafters 703 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Exterior insulation layer 2: Isorigid
Exterior insulation layer 1: ISOVER PB M 030
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario KM Supraplex-SKS
Covering below 1st layer: Wood panel for structural purposes ≥ 450 kg/m³
Covering below 2nd layer: Rib/bar

Insulation between and on supporting structure with covering 184 kg/m2 -3 dB
Calculation ≈ 0.082 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File) XLSX Test report PDF