Filter Catalog Steep roof

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 5 of 6. There were 117 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

E0200

Ribs / rafters 385 mm 48 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A

Insulation between the supporting structure of covering 82 kg/m2 -3 dB
Calculation ≈ 0.151 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0201

Ribs / rafters 405 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A

Insulation between the supporting structure of covering 84 kg/m2 -3 dB
Calculation ≈ 0.142 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0202

Ribs / rafters 425 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A

Insulation between the supporting structure of covering 87 kg/m2 -3 dB
Calculation ≈ 0.133 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0203

Ribs / rafters 445 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A

Insulation between the supporting structure of covering 89 kg/m2 -3 dB
Calculation ≈ 0.126 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0204

Ribs / rafters 377 mm 54 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 86 kg/m2 -3 dB
Calculation ≈ 0.172 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0205

Ribs / rafters 397 mm 54 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 89 kg/m2 -3 dB
Calculation ≈ 0.16 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0206

Ribs / rafters 417 mm 54 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 91 kg/m2 -3 dB
Calculation ≈ 0.149 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0207

Ribs / rafters 437 mm 56 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 93 kg/m2 -3 dB
Calculation ≈ 0.14 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0208

Ribs / rafters 457 mm 56 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 96 kg/m2 -3 dB
Calculation ≈ 0.132 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0209

Ribs / rafters 477 mm 56 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A

Insulation between the supporting structure of covering 98 kg/m2 -3 dB
Calculation ≈ 0.125 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0210

Ribs / rafters 355 mm 47 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 77 kg/m2 -3 dB
Calculation ≈ 0.143 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0211

Ribs / rafters 375 mm 47 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 80 kg/m2 -3 dB
Calculation ≈ 0.125 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0212

Ribs / rafters 395 mm 47 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 82 kg/m2 -3 dB
Calculation ≈ 0.119 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0213

Ribs / rafters 415 mm 49 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 85 kg/m2 -3 dB
Calculation ≈ 0.106 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0214

Ribs / rafters 435 mm 49 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 87 kg/m2 -3 dB
Calculation ≈ 0.101 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0215

Ribs / rafters 455 mm 50 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure 91 kg/m2 -3 dB
Calculation ≈ 0.301 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)

E0216

Ribs / rafters 420 mm 58 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure of covering 95 kg/m2 -3 dB
Calculation ≈ 0.14 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0217

Ribs / rafters 460 mm 58 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure of covering 97 kg/m2 -3 dB
Calculation ≈ 0.132 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0218

Ribs / rafters 480 mm 58 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure of covering 100 kg/m2 -3 dB
Calculation ≈ 0.125 W/m2K -9 dB
Detail IFC4 LOD300 (Missing File)

E0219

Ribs / rafters 500 mm 60 dB
Roofing: Roof tiles
Battens / profiles: Wood laths 48x48 + roof laths 48x24mm e=350mm
Under the roof: Roofing underlay
Sub-floor: Isorigid
Bond: Stiff, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: ISOVER PB M 030
Vapor barrier: Vario Xtra
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Cavity dampening: ISOVER PB M 030
Covering below 1st layer: Plasterboard type A
Covering below 2nd layer: Plasterboard type A
Surface below: Round profile paneling / Softline, VSH profile no. 26

Insulation between the supporting structure of covering 102 kg/m2 -3 dB
Calculation ≈ 0.118 W/m2K -10 dB
Detail IFC4 LOD300 (Missing File)