Filter Catalog Outer wall

General Information

Consider the spectrum adaptation term:

Environmental impact per m2 component by indicator

Manufacture and disposal, without taking into account the amortization periods according to SIA 2032

Hide products without information
Hide products without information
Hide products without information
Hide products without information

Assembly

Manufacturer

Search assembly number

INFO: If you search for the Part Number , are all above Filter ignored and adapted to the new results.
Page 5 of 8. There were 157 matching component found.
Lignum ID-№ Base structure Construction height Values of airborne sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

D0990

Stud 368 mm 47 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 97 kg/m2 -1 dB
Calculation ≈ 0.182 W/m2K -4 dB
Detail IFC4 LOD300

D0991

Stud 408 mm 47 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 99 kg/m2 -1 dB
Calculation ≈ 0.161 W/m2K -4 dB
Detail IFC4 LOD300

D0992

Stud 468 mm 48 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 103 kg/m2 -1 dB
Calculation ≈ 0.137 W/m2K -4 dB
Detail IFC4 LOD300

D0993

Stud 528 mm 49 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 107 kg/m2 -1 dB
Calculation ≈ 0.119 W/m2K -4 dB
Detail IFC4 LOD300

D0994

Stud 308 mm 47 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 74 kg/m2 -1 dB
Calculation ≈ 0.201 W/m2K -7 dB
Detail IFC4 LOD300

D0995

Stud 348 mm 47 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 76 kg/m2 -1 dB
Calculation ≈ 0.176 W/m2K -7 dB
Detail IFC4 LOD300

D0996

Stud 368 mm 48 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 78 kg/m2 -1 dB
Calculation ≈ 0.165 W/m2K -7 dB
Detail IFC4 LOD300

D0997

Stud 428 mm 49 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 81 kg/m2 -1 dB
Calculation ≈ 0.14 W/m2K -7 dB
Detail IFC4 LOD300

D0999

Stud 321 mm 47 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 81 kg/m2 0 dB
Calculation ≈ 0.198 W/m2K -6 dB
Detail IFC4 LOD300

D1000

Stud 341 mm 47 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 83 kg/m2 0 dB
Calculation ≈ 0.184 W/m2K -6 dB
Detail IFC4 LOD300

D1001

Stud 381 mm 48 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 85 kg/m2 0 dB
Calculation ≈ 0.163 W/m2K -6 dB
Detail IFC4 LOD300

D1002

Stud 441 mm 49 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 89 kg/m2 0 dB
Calculation ≈ 0.138 W/m2K -6 dB
Detail IFC4 LOD300

D1003

Stud 501 mm 50 dB
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 93 kg/m2 0 dB
Calculation ≈ 0.12 W/m2K -6 dB
Detail IFC4 LOD300

D1004

Stud 323 mm 45 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 92 kg/m2 -1 dB
Calculation ≈ 0.201 W/m2K -5 dB
Detail IFC4 LOD300

D1005

Stud 363 mm 45 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 95 kg/m2 -1 dB
Calculation ≈ 0.176 W/m2K -5 dB
Detail IFC4 LOD300

D1006

Stud 383 mm 46 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 96 kg/m2 -1 dB
Calculation ≈ 0.165 W/m2K -5 dB
Detail IFC4 LOD300

D1007

Stud 443 mm 48 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 100 kg/m2 -1 dB
Calculation ≈ 0.14 W/m2K -5 dB
Detail IFC4 LOD300

D1008

Stud 523 mm 49 dB
Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Vapor-permeable water barrier
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 105 kg/m2 -1 dB
Calculation ≈ 0.116 W/m2K -5 dB
Detail IFC4 LOD300

D1009

BRESTA Solid Timber System 320 mm 45 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 92 kg/m2 -1 dB
Calculation ≈ 0.212 W/m2K -7 dB
Detail IFC4 LOD300

D1010

BRESTA Solid Timber System 340 mm 45 dB
Cover leftside 1st layer: Wood cladding horizontal, closed
Battens / profiles (ventilation): Wood lath transversely b=60mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Ventilated facade 95 kg/m2 -1 dB
Calculation ≈ 0.198 W/m2K -7 dB
Detail IFC4 LOD300