E0180
Ribs / rafters
578
mm
R
w
51
dB
Insulation between the supporting structure of covering
120
kg/m2
C
-5
dB
Calculation
≈
0.126
W/m2 K
C
tr
-11
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0181
Ribs / rafters
658
mm
R
w
52
dB
Insulation between the supporting structure of covering
135
kg/m2
C
-5
dB
Calculation
≈
0.109
W/m2 K
C
tr
-11
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0182
Ribs / rafters
356
mm
R
w
47
dB
Insulation between the supporting structure of covering
76
kg/m2
C
-4
dB
Calculation
≈
0.177
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0183
Ribs / rafters
416
mm
R
w
48
dB
Insulation between the supporting structure of covering
82
kg/m2
C
-4
dB
Calculation
≈
0.147
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0184
Ribs / rafters
436
mm
R
w
48
dB
Insulation between the supporting structure of covering
84
kg/m2
C
-4
dB
Calculation
≈
0.139
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0185
Ribs / rafters
516
mm
R
w
49
dB
Insulation between the supporting structure of covering
92
kg/m2
C
-4
dB
Calculation
≈
0.114
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0186
Ribs / rafters
596
mm
R
w
50
dB
Insulation between the supporting structure of covering
100
kg/m2
C
-4
dB
Calculation
≈
0.097
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0187
Ribs / rafters
383
mm
R
w
55
dB
Insulation between the supporting structure of covering
82
kg/m2
C
-6
dB
Calculation
≈
0.179
W/m2 K
C
tr
-14
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0188
Ribs / rafters
423
mm
R
w
57
dB
Insulation between the supporting structure of covering
86
kg/m2
C
-6
dB
Calculation
≈
0.157
W/m2 K
C
tr
-14
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0189
Ribs / rafters
463
mm
R
w
59
dB
Insulation between the supporting structure of covering
90
kg/m2
C
-6
dB
Calculation
≈
0.14
W/m2 K
C
tr
-14
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0190
Ribs / rafters
543
mm
R
w
62
dB
Insulation between the supporting structure of covering
98
kg/m2
C
-6
dB
Calculation
≈
0.114
W/m2 K
C
tr
-14
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0191
Ribs / rafters
623
mm
R
w
64
dB
Insulation between the supporting structure of covering
106
kg/m2
C
-5
dB
Calculation
≈
0.097
W/m2 K
C
tr
-13
dB
Detail
IFC4 LOD300
XLSX
Test report PDF
E0192
Ribs / rafters
345
mm
R
w
43
dB
Insulation between the supporting structure
74
kg/m2
C
-3
dB
Calculation
≈
0.172
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0193
Ribs / rafters
365
mm
R
w
43
dB
Insulation between the supporting structure
77
kg/m2
C
-3
dB
Calculation
≈
0.16
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0194
Ribs / rafters
385
mm
R
w
43
dB
Insulation between the supporting structure
79
kg/m2
C
-3
dB
Calculation
≈
0.15
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0195
Ribs / rafters
405
mm
R
w
45
dB
Insulation between the supporting structure
81
kg/m2
C
-3
dB
Calculation
≈
0.141
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0196
Ribs / rafters
425
mm
R
w
45
dB
Insulation between the supporting structure
84
kg/m2
C
-3
dB
Calculation
≈
0.133
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0197
Ribs / rafters
445
mm
R
w
45
dB
Insulation between the supporting structure
86
kg/m2
C
-3
dB
Calculation
≈
0.125
W/m2 K
C
tr
-10
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0198
Ribs / rafters
345
mm
R
w
48
dB
Insulation between the supporting structure of covering
77
kg/m2
C
-3
dB
Calculation
≈
0.174
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF
E0199
Ribs / rafters
365
mm
R
w
48
dB
Insulation between the supporting structure of covering
80
kg/m2
C
-3
dB
Calculation
≈
0.161
W/m2 K
C
tr
-9
dB
Detail
IFC4 LOD300
(Missing File)
XLSX
Test report PDF