Lignum ID-№ Base structure Construction height Values of airborne sound insulation Values of footfall sound insulation
Graphic Paneling Weight
Origin of sound insulation values U-value

A2220

BRESTA Solid Timber System 565 mm 74 dB 39 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Dampening on Supporting structure: Cement screed with EPS
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel

with floor construction 688 kg/m2 -2 dB -7 dB
Calculation ≈ 0.217 W/m2K 0 dB 1 dB
Detail IFC4 LOD300

A2221

BRESTA Solid Timber System 605 mm 74 dB 39 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Dampening on Supporting structure: Cement screed with EPS
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel

with floor construction 745 kg/m2 -2 dB -7 dB
Calculation ≈ 0.21 W/m2K 0 dB 1 dB
Detail IFC4 LOD300

A2222

BRESTA Solid Timber System 625 mm 75 dB 38 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Dampening on Supporting structure: Cement screed with EPS
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel

with floor construction 755 kg/m2 -2 dB -7 dB
Calculation ≈ 0.203 W/m2K 0 dB 1 dB
Detail IFC4 LOD300

A2223

BRESTA Solid Timber System 665 mm 75 dB 38 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Dampening on Supporting structure: Cement screed with EPS
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel

with floor construction 812 kg/m2 -2 dB -7 dB
Calculation ≈ 0.196 W/m2K 0 dB 1 dB
Detail IFC4 LOD300

A2224

BRESTA Solid Timber System 351 mm 69 dB 46 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 468 kg/m2 -2 dB -7 dB
Calculation ≈ 0.331 W/m2K -6 dB 2 dB
Detail IFC4 LOD300

A2225

BRESTA Solid Timber System 391 mm 70 dB 45 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 525 kg/m2 -2 dB -7 dB
Calculation ≈ 0.314 W/m2K -6 dB 1 dB
Detail IFC4 LOD300

A2226

BRESTA Solid Timber System 431 mm 71 dB 44 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 583 kg/m2 -2 dB -7 dB
Calculation ≈ 0.298 W/m2K -6 dB 1 dB
Detail IFC4 LOD300

A2227

BRESTA Solid Timber System 451 mm 71 dB 44 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 592 kg/m2 -2 dB -7 dB
Calculation ≈ 0.285 W/m2K -6 dB 1 dB
Detail IFC4 LOD300

A2228

BRESTA Solid Timber System 491 mm 72 dB 43 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 650 kg/m2 -2 dB -7 dB
Calculation ≈ 0.272 W/m2K -6 dB 1 dB
Detail IFC4 LOD300

A2229

BRESTA Solid Timber System 531 mm 74 dB 41 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 707 kg/m2 -2 dB -7 dB
Calculation ≈ 0.26 W/m2K -6 dB 1 dB
Detail IFC4 LOD300

A2230

BRESTA Solid Timber System 551 mm 75 dB 40 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 717 kg/m2 -2 dB -7 dB
Calculation ≈ 0.25 W/m2K -6 dB 1 dB
Detail IFC4 LOD300

A2231

BRESTA Solid Timber System 591 mm 75 dB 39 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Bond: Stiff, execution of the prior art.
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 774 kg/m2 -2 dB -7 dB
Calculation ≈ 0.24 W/m2K -6 dB 1 dB
Detail IFC4 LOD300

A2232

BRESTA Solid Timber System 458 mm 80 dB 35 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 477 kg/m2 -6 dB 3 dB
Calculation ≈ 0.325 W/m2K -8 dB 15 dB
Detail IFC4 LOD300

A2233

BRESTA Solid Timber System 498 mm 81 dB 34 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 535 kg/m2 -6 dB 3 dB
Calculation ≈ 0.308 W/m2K -8 dB 15 dB
Detail IFC4 LOD300

A2234

BRESTA Solid Timber System 538 mm 81 dB 33 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 592 kg/m2 -6 dB 3 dB
Calculation ≈ 0.293 W/m2K -8 dB 15 dB
Detail IFC4 LOD300

A2235

BRESTA Solid Timber System 558 mm 82 dB 33 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 602 kg/m2 -6 dB 3 dB
Calculation ≈ 0.28 W/m2K -8 dB 15 dB
Detail IFC4 LOD300

A2236

BRESTA Solid Timber System 598 mm 83 dB 32 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 659 kg/m2 -6 dB 3 dB
Calculation ≈ 0.268 W/m2K -8 dB 15 dB
Detail IFC4 LOD300

A2237

BRESTA Solid Timber System 638 mm 84 dB 30 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 716 kg/m2 -6 dB 3 dB
Calculation ≈ 0.257 W/m2K -8 dB 15 dB
Detail IFC4 LOD300

A2238

BRESTA Solid Timber System 658 mm 84 dB 30 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 726 kg/m2 -6 dB 3 dB
Calculation ≈ 0.247 W/m2K -8 dB 15 dB
Detail IFC4 LOD300

A2239

BRESTA Solid Timber System 698 mm 85 dB 29 dB
Flooring: Fllor
On-lying material: Cement screed
Impact sound insulation: Wood fiber generic product
Sub-floor: Construction concrete, CEM II / A (cement content 290 kg/m³)
Bond: Rigid, execution of the prior art.
Supporting structure: Bresta Solid timber panel
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: Wood lath b=60mm
Ceiling covering 1st layer: Plasterboard type A
Ceiling covering layer 2: Plasterboard type A
Surface / treatment: Innenputz, verspachtelt

with floor construction and ceiling covering 783 kg/m2 -6 dB 3 dB
Calculation ≈ 0.237 W/m2K -8 dB 15 dB
Detail IFC4 LOD300