Values of airborne sound insulation | |
---|---|
Rw | 64 dB |
C | -2 dB |
Ctr | -7 dB |
Values of footfall sound insulation | |
---|---|
Ln,w | 35 dB |
CI | 5 dB |
CI50-2500 | dB |
Layer | Product | Manufacturer | Thickness [mm] | Weight | Width (b) | Axial distance (e) | KBOB ID-№ Production | KBOB ID-№ Disposal |
---|---|---|---|---|---|---|---|---|
Use and protection layer 3 | Solid timber b=80-150mm e=b+7mm | Generic product | 21 mm | 10.5 kg/m2 | - | - | 07.009 | 91.052 |
Use and protection layer 1 | Wood lath b=48mm | Generic product, Label swiss wood | 60 mm | 29.4 kg/m2 | - | - | 07.011 | 91.052 |
Separating layer | Sylomer R 12 blue | Getzner Werkstoffe | 10 mm | 0.1 kg/m2 | - | - | 10.006 | 91.039 |
Covering upside 1st layer | Concrete panels | Generic product | 40 mm | 94.8 kg/m2 | - | - | 02.007 | 91.136 |
Under the roof | Sealing sheet rubber (EPDM) | Generic product | 2.5 mm | 2.8 kg/m2 | - | - | 09.004 | 91.147 |
Exterior insulation layer 2 | Expanded polystyrene (EPS) | Swisspor, Sager | 200 mm | 3 kg/m2 | - | - | 10.004 | 91.151 |
Sheathed above 1st layer | OSB / 3 slabs for load-bearing purposes for use in damp conditions | Generic product, Willisauerstrasse 37, Sonae Arauco SA, Egger, Norbord Europe Ltd. | 22 mm | 14.3 kg/m2 | - | - | 07.013 | 91.145 |
Support | Ribs Lignotrend Q3 | Lignotrend | 164 mm | 43 kg/m2 | 71.7 mm | 134 mm | 07.011 | 91.052 |
Dampening in supporting structure | Edelsplitt 2/5 | Generic product | 95 mm | 61.9 kg/m2 | - | - | 03.011 | 91.062 |
Lower skin layer 1 | Unifying panel on the underside HBF 40mm (20+20mm) | Lignotrend | 32 mm | 15.7 kg/m2 | - | - | 07.001 | 91.048 |
Color | Type | 25 | 32 | 40 | 50 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | 315 | 400 | 500 | 630 | 800 | 1000 | 1250 | 1600 | 2000 | 2500 | 3150 | 4000 | 5000 | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airborne sound (R) | Measurement | Ift Rosenheim | 32 | 31 | 38 | 42 | 46 | 44 | 48 | 54 | 61 | 60 | 60 | 63 | 71 | 76 | 79 | 79 | 80 | 81 | 81 | 85 | 86 | |||
Calculation | Lignum/Kühn and Blickle | 7 | 8 | 7 | 15 | 23 | 31 | 36 | 39 | 46 | 52 | 58 | 64 | 71 | 77 | 82 | 88 | 94 | 100 | 106 | 110 | 110 | 110 | |||
Impact sound (Ln) | Measurement | Ift Rosenheim | 59 | 59 | 55 | 54 | 46 | 40 | 34 | 30 | 29 | 31 | 30 | 29 | 28 | 23 | 17 | 13 | 12 | 8 | 7 | 7 | 7 | |||
Calculation | Lignum/Kühn and Blickle | 73 | 76 | 80 | 75 | 70 | 65 | 63 | 62 | 59 | 56 | 53 | 49 | 46 | 43 | 41 | 38 | 35 | 32 | 29 | 26 | 21 | 16 |
bSDD Properties | ||||||||
---|---|---|---|---|---|---|---|---|
mm | Indicators | Modules | ||||||
Values / m2 | ||||||||
+
|
Environmental impact points (UBP)
|
141108
|
UBP'21/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Environmental impact points from production (UBP_pro)
|
110144
|
UBP'21/m2
|
A1-A3
|
|||
|
┗
|
Environmental impact points from disposal (UBP_dis)
|
30984
|
UBP'21/m2
|
C1-C4
|
|||
+
|
Total primary energy (PE_T)
|
1138.60
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Primary energy from production (PE_pro)
|
1120.90
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Primary energy production, energetically consumed (PE_E_pro)
|
485.20
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Primary energy production, materially bound (PE_M_pro)
|
636.40
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Primary energy from disposal (PE_dis)
|
17.40
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Renewable primary energy (PE_RT)
|
823.30
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Renewable primary energy from production (PE_RT_pro)
|
822.00
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
|
248.60
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Renewable primary energy from production, materially bound (PE_RM_pro)
|
572.70
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Renewable primary energy from disposal (PE_RT_dis)
|
1.00
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Total use of non- renewable primary energy resources (PE_NRT)
|
316.00
|
kWh oil-eq/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Primary energy not renewable from manufacturing (PE_NRT_pro)
|
299.40
|
kWh oil-eq/m2
|
A1-A3
|
|||
|
┃
|
┣
|
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
|
236.00
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┃
|
┗
|
Primary energy not renewable from production, materially bound (PE_NRM_pro)
|
63.60
|
kWh oil-eq/m2
|
A1-A3
|
||
|
┗
|
Primary energy not renewable from disposal (PE_NRT_dis)
|
16.50
|
kWh oil-eq/m2
|
C1-C4
|
|||
+
|
Total greenhouse gas emissions (GWP_total)
|
80.60
|
kg CO2/m2
|
A1-A3 + C1-C4
|
||||
|
┣
|
Greenhouse gas emissions from manufacturing (GWP_pro)
|
56.30
|
kg CO2/m2
|
A1-A3
|
|||
|
┗
|
Greenhouse gas emissions from waste disposal (GWP_dis)
|
24.40
|
kg CO2/m2
|
C1-C4
|
|||
|
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
|
183.70
|
kg CO2/m2
|
B1-B7
|
||||
|
Biogenic carbon storage (bio-C) (Not included in GWP)
|
50.10
|
kg C/m2
|
B1-B7
|
||||
⇒ Advantages of the life cycle assessment outside the system boundary (module D) |