LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly D0978

Lignum ID-№
D0978
Catalog number
D.1.02.AW310E
Source of construction assembly
Tschopp, Year 2017
Base structure
Stud
Type of facade
Ventilated facade and wall covering
Paneling
Without substructure, directly sheathed
Construction height
542 mm
Weight
116 kg/m2
U-value
≈ 0.112 W/m2K
GWP
49.60 kg CO2-eq/m2
Type sound insulation
Calculation
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside single sheathed, roomside single sheathed. Simple covering. Ventilated facade.
Values of airborne sound insulation
Rw 50 dB
C -1 dB
Ctr -7 dB

Graphic

Surface 1: Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish
Cover leftside 1st layer: mineral, cement-based building board
Battens / profiles (ventilation): Wood lath transversely b=80mm
Sheathed outside leftside 1st layer: Wood fiber board ≥ 180kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Cellulose: Loose; not monitored
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Bresta Solid timber panel
Covering rightside1st layer: Plasterboard type A
Surface rightside: Smoothed joints

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface 1 Exterior finish system suitable for supporting panel. Consisting of basic coating, fabric reinforcement and finish Generic product 10 mm 13.3 kg/m2 - - 04.011 91.139
Cover leftside 1st layer mineral, cement-based building board Fermacell, Knauf, Rigips 13 mm 15.6 kg/m2 - - 03.003 91.137
Battens / profiles (ventilation) Wood lath transversely b=80mm Generic product, Origin mark Swiss wood 40 mm 2.5 kg/m2 80 mm 625 mm 07.011 91.052
Sheathed outside leftside 1st layer Wood fiber board ≥ 180kg/m³ Gutex, Isover 20 mm 3.6 kg/m2 - - 10.009 91.051
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood 360 mm 11.9 kg/m2 40 mm 595 mm 07.003.01 91.047
Cavity dampening Cellulose: Loose; not monitored Generic product 360 mm 18 kg/m2 - - 10.010 91.046
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Bresta Solid timber panel Tschopp 87 mm 42.6 kg/m2 - - 07.011.02 91.052
Covering rightside1st layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064
Surface rightside Smoothed joints Knauf, Rigips - - - - 04.017 91.139

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 21 23 25 27 29 29 28 31 40 47 54 61 68 74 79 85 91 97 103 109 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
95391.1
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
86054
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
9516.8
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
774.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
763.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
442.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
323.1
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
11.3
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
579.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
578.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
258.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
320.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.7
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
197
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
186.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
183.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
2.9
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
10.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
49.6
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
45.3
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
125.40000000000002
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
34.2
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)