Components

Construction assembly D1233

Lignum ID-№
D1233
Catalog number
D.1.01.AW.60.HL_GF/GF
Source of construction assembly
23-073-1 PB Pfleiderer Wand Typ02_4-11, Year 2024
Base structure
Stud
Type of facade
Ventilated facade
Paneling
Without covering
Construction height
244 mm
Weight
72 kg/m2
U-value
≈ 0.196 W/m2K
GWP
30.30 kg CO2-eq/m2
Type sound insulation
Calculation without verification
Outer wall consisting of a basic construction of stud with cavity insulation in the supporting structure. Sheathed outside & interior, on the outside twice sheathed, roomside double sheathed. Without covering. Ventilated facade.
Values of airborne sound insulation
Rw 46 dB
C -2 dB
Ctr -7 dB

Graphic

Cover leftside 1st layer: Duropal Xterior Compact F
Battens / profiles (ventilation): Wood lath b=60mm
Coupling: Facade membranes
Sheathed outside leftside 2nd layer: GKFI/DFH2IR Knauf Diamant hard- plasterboard
Sheathed outside leftside 1st layer: StyleBoard MDF.RWH
Bond: Stiff, execution of the prior art.
Support: Finger-jointed solid wood width = 60mm
Cavity dampening: Cellulose insulation CLIMACELL
Bond: Rigid, execution of the prior art.
Sheathed rightside 1st layer: LivingBoard P5
Sheathed rightside 2nd layer: Plasterboard type A

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Cover leftside 1st layer Duropal Xterior Compact F Pfleiderer 8 mm 11.2 kg/m2 - - - -
Battens / profiles (ventilation) Wood lath b=60mm Generic product, Label swiss wood 20 mm 1.4 kg/m2 60 mm 417 mm 07.011 91.052
Coupling Facade membranes Generic product 0.4 mm 0.2 kg/m2 - - 09.008 91.037
Sheathed outside leftside 2nd layer GKFI/DFH2IR Knauf Diamant hard- plasterboard Knauf 12.5 mm 13.8 kg/m2 - - 03.007 91.063
Sheathed outside leftside 1st layer StyleBoard MDF.RWH Pfleiderer 16 mm 9.6 kg/m2 - - 07.012 91.050
Bond Stiff, execution of the prior art. - - - - - - -
Support Finger-jointed solid wood width = 60mm General Informations, Generic product, August Brühwiler, Dahinden Sägewerk, Filippi, Necker Holz, Schilliger Holz, Origin mark Swiss wood 160 mm 7.5 kg/m2 60 mm 625 mm 07.011 91.052
Cavity dampening Cellulose insulation CLIMACELL Catolet 160 mm 8.8 kg/m2 - - 10.010 91.046
Bond Rigid, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer LivingBoard P5 Pfleiderer 15 mm 10.5 kg/m2 - - 07.015 91.145
Sheathed rightside 2nd layer Plasterboard type A Knauf, Rigips 12.5 mm 9.2 kg/m2 - - 03.008 91.064

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement MFPA Leipzig 27 23 26 26 27 27 28 37 38 40 43 45 49 52 55 56 54 51 54 60 65
Calculation Lignum/Kühn and Blickle 14 17 19 22 25 27 29 29 31 34 37 40 42 44 45 45 45 54 63 70 79 88

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
51572.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
45081.2
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
6480.1
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
298.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
292.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
141.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
150.8
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
6.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
161
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
160.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
32.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
128.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
137.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
131.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
109
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
22.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
30.3
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
26.5
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
3.7
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
59.4
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
16.2
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)