LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A1091

Lignum ID-№
A1091
Catalog number
A.3.03.A29
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
305 mm
Weight
209 kg/m2
U-value
≈ 0.282 W/m2K
GWP
43.40 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of solid timber, without sheathing, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 30 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 56 dB
C -3 dB
C50-3150 -3 dB
Values of footfall sound insulation
Ln,w 59 dB
CI 0 dB
CI50-2500 1 dB

Graphic

On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 23 mm 28.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] Gutex, Isover 22 mm 3.5 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 60 mm 84 kg/m2 - - 03.011 91.062
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 200 mm 94 kg/m2 1000 mm 1000 mm 07.002 91.047

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 29 31 34 35 33 35 41 47 52 58 63 67 72 77 81 86 91 99 106
Calculation Lignum/Kühn and Blickle 32 34 37 40 42 45 47 46 43 46 42 45 48 50 50 50 51 60 68 75 84 92
Impact sound (Ln) Measurement Lignum Berechnung 60 60 61 63 68 69 66 63 60 58 56 55 53 51 49 48 46 41 37
Calculation Lignum/Kühn and Blickle 49 50 50 50 51 51 52 56 62 63 69 69 69 70 73 76 78 72 67 63 57 51

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
99082.4
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
85938.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13135.8
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
983.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
966.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
458.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
507.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
16.6
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
781.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
780.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
282.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
497.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.9
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
201.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
186.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
176.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
9.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
15.7
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
43.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
36.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
6.5
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
164.26666666666665
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
44.8
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)