LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0480

Lignum ID-№
C0480
Catalog number
C.3.03.KROE2.1
Source of construction assembly
Kronoply GmbH, Year 2009
Base structure
Solid wood panel
Sheathing
without sheathing
Paneling
Covering on one side
Reference fire protection
Lignum Dok. 4.1, Tabelle: 44X
Construction height
185 mm
Weight
98 kg/m2
U-value
≈ 0.318 W/m2K
GWP
60.00 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofsolid timber without cavity insulation in the supporting structure. without sheathing. Covering on one side with cavity insulation.
Values of airborne sound insulation
Rw 61 dB
C dB
C50-3150 dB

Graphic

Surface leftside: Smoothed joints
Cover leftside 2nd layer: Rigidur H-Gipsfaserplatte
Cover leftside 1st layer: Rigidur H-Gipsfaserplatte
Battens / profiles: CW-wall profile b=50mm
Coupling: Air
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: no composite action
Support: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Smoothed joints Knauf, Rigips - - - - 04.017 91.139
Cover leftside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Cover leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Battens / profiles CW-wall profile b=50mm Fermacell, Knauf, Rigips, Protektor 50 mm 1.1 kg/m2 50 mm 625 mm 06.011 91.143
Coupling Air - 10 mm - - - - -
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 50 mm 1.6 kg/m2 - - 10.008 91.173
Bond no composite action - - - - - - -
Support SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 24 26 29 32 34 37 39 38 35 37 34 37 40 42 42 42 43 52 60 67 76 85

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
113354
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
103889.4
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
9324.3
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
829.5
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
820.3
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
446.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
371.6
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
9.6
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
552.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
551.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
215.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
335.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.6
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
275.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
266.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
231.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
35.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
9
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
60
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
54
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.9
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
30.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)