LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly B0323

Lignum ID-№
B0323
Catalog number
B.3.01.KRO A3.1
Source of construction assembly
Prüfbericht 040204.V02, Year 2009
Base structure
Solid wood panel
Sheathing
Sheathed on one side
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 44X
Construction height
390 mm
Weight
195 kg/m2
U-value
≈ 0.181 W/m2K
GWP
90.90 kg CO2-eq/m2
Type sound insulation
Measurement
Partition wall double shell consisting of a basic construction of solid timber without cavity insulation in the supporting structure. Sheathed in the interspace.Without covering. With cavity insulation between the wall panels.
Values of airborne sound insulation
Rw 62 dB
C -2 dB
C50-3150 -2 dB

Graphic

Support leftside: SWISS KRONO MAGNUMBOARD OSB
Bond: Stiff, execution of the prior art.
Sheathed outside leftside 1st layer: Rigidur H-Gipsfaserplatte
Sheathed outside leftside 2nd layer: Rigidur H-Gipsfaserplatte
Intermediate insulation: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Air gap: Air
Sheathed far rightside 2nd layer: Rigidur H-Gipsfaserplatte
Sheathed outside rightside 1st layer: Rigidur H-Gipsfaserplatte
Bond: Stiff, execution of the prior art.
Support rightside: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Support leftside SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed outside leftside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Sheathed outside leftside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Intermediate insulation Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 120 mm 3.8 kg/m2 - - 10.008 91.173
Air gap Air - 20 mm - - - - -
Sheathed far rightside 2nd layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Sheathed outside rightside 1st layer Rigidur H-Gipsfaserplatte Rigips 12.5 mm 15 kg/m2 - - 03.007 91.063
Bond Stiff, execution of the prior art. - - - - - - -
Support rightside SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement LSW Stephanskirchen bei Rosenheim 42 50 46 53 50 52 53 54 52 56 66 75 81 85 88 90 90 87 86 84 80
Calculation Lignum/Kühn and Blickle 21 22 21 26 35 43 49 52 53 59 59 65 72 78 83 89 94 100 107 110 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
162150
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
145734
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
16137
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1529.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1513.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
765.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
743.2
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
16.2
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
1093.3
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
1091.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
420
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
671.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.9
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
431.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
416.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
346.3
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
70.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
15.2
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
90.9
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
79.8
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
11.1
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
60
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)