LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly B9396

Lignum ID-№
B9396
Catalog number
B.3.02.21001299/W05
Source of construction assembly
21-001299-PRO1 PB W06-F02-04-de-01, Year 2021
Base structure
Solid timber, derived wood products
Sheathing
without sheathing
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 447
Construction height
605 mm
Weight
175 kg/m2
U-value
≈ 0.086 W/m2K
GWP
87.50 kg CO2-eq/m2
Type sound insulation
Measurement
Partition wall double shell consisting of a basic construction of solid timber, derived wood product without cavity insulation in the supporting structure. without sheathing.Double covering, with cavity insulation. With cavity insulation between the wall panels.
Values of airborne sound insulation
Rw 83 dB
C -2 dB
C50-3150 -4 dB

Graphic

Surface leftside: Glued joints/smoothed
Cover leftside 2nd layer: GKF/DF Knauf Piano
Cover leftside 1st layer: GKF/DF Knauf Piano
Battens / profiles: CD-ceiling profile b=60mm
Support leftside: SWISS KRONO MAGNUMBOARD OSB
Bond: Stiff, execution of the prior art.
Intermediate insulation: Rockwool ≥ 60kg/m³
Air gap: Air
Intermediate insulation: Rockwool ≥ 60kg/m³
Bond: Stiff, execution of the prior art.
Support rightside: SWISS KRONO MAGNUMBOARD OSB

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Surface leftside Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -
Cover leftside 2nd layer GKF/DF Knauf Piano Knauf 12.5 mm 10 kg/m2 - - 03.008 91.064
Cover leftside 1st layer GKF/DF Knauf Piano Knauf 12.5 mm 10 kg/m2 - - 03.008 91.064
Battens / profiles CD-ceiling profile b=60mm Fermacell, Knauf, Rigips, Protektor 50 mm 1.6 kg/m2 - 625 mm 06.011 91.143
Support leftside SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -
Intermediate insulation Rockwool ≥ 60kg/m³ Generic product 140 mm - - - 10.008 91.173
Air gap Air - 50 mm - - - - -
Intermediate insulation Rockwool ≥ 60kg/m³ Generic product 140 mm - - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Support rightside SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 100 mm 66 kg/m2 1000 mm 1000 mm 07.013 91.145

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 47 52 56 62 64 66 65 74 74 75 81 85 88 90 95 99 98 95 93 91 84
Calculation Lignum/Kühn and Blickle 22 23 23 23 29 38 45 48 49 55 55 62 68 74 79 85 91 97 103 109 110 110

Airborne sound (R)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
170602.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
154926.2
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
15443.7
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1507.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1492.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
744.2
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
743.2
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
15.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
1094.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
1092.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
421.1
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
671.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.9
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
409.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
394.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
324.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
70.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
14.4
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
87.5
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
76.59999999999998
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
11
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
59
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)