LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2738

Lignum ID-№
A2738
Catalog number
A.1.03.--
Source of construction assembly
980202.T22-120, Year 1998
Base structure
Ribs / joists
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 431 (Balken) oder 432 (Rippen) Gilt nicht für Bauteile mit Beschwerung im Hohlraum.
Construction height
323 mm
Weight
223 kg/m2
U-value
≈ 0.275 W/m2K
GWP
42.50 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of ribs / joists, single sheathed, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation and with dry screed.
Values of airborne sound insulation
Rw dB
C dB
C50-3150 dB
Values of footfall sound insulation
Ln,w 47 dB
CI 1 dB
CI50-2500 dB

Graphic

Flooring: Chipboard
On-lying material: multifix
Impact sound insulation: PhoneStar 25
Additional insulation: Thermofloor
Sub-floor: Standard-n
Supporting structure: Ribs Lignotrend Q3
Dampening in supporting structure: Gravel of lime 3-6 mm
Lower skin layer 1: Unifying panel on the underside HBF 40mm (20+20mm)

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Flooring Chipboard Generic product 13 mm 7.8 kg/m2 - - 07.015 91.145
On-lying material multifix Gutex 30 mm 20.4 kg/m2 - - 10.009 91.051
Impact sound insulation PhoneStar 25 Wolf Bavaria 30 mm 46.8 kg/m2 - - 03.013 91.062
Additional insulation Thermofloor Gutex 30 mm 4.8 kg/m2 - - 10.009 91.051
Sub-floor Standard-n Gutex 6 mm 1.5 kg/m2 - - 10.009 91.051
Supporting structure Ribs Lignotrend Q3 Lignotrend 175 mm 45.9 kg/m2 71.7 mm 134 mm 07.011 91.052
Dampening in supporting structure Gravel of lime 3-6 mm Generic product 95 mm 77.3 kg/m2 - - 03.011 91.062
Lower skin layer 1 Unifying panel on the underside HBF 40mm (20+20mm) Lignotrend 39 mm 19.1 kg/m2 - - 07.001 91.048

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Calculation Lignum/Kühn and Blickle 11 13 16 19 21 24 26 25 28 30 33 36 39 41 41 41 42 51 59 66 75 84
Impact sound (Ln) Measurement Ift Rosenheim 64 64 60 59 57 53 50 45 46 50 45 42 38 34 28 23 20 16 12 8 8
Calculation Lignum/Kühn and Blickle 70 71 71 71 72 72 73 77 77 78 78 78 78 79 82 85 87 81 76 72 66 60

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
93213
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
77142
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
16297
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
952.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
935.60
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
412.50
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
524.00
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
18.20
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
756.30
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
755.30
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
257.60
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
496.70
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.10
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
198.30
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
181.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
153.90
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
27.30
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
17.20
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
42.50
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
35.00
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7.50
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
160.97
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
43.90
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)