Components

Construction assembly A2711

Lignum ID-№
A2711
Catalog number
A.3.01.21001299/D05
Source of construction assembly
Swiss Krono, Year 2021
Base structure
Solid timber, derived wood products
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 43X
Construction height
380 mm
Weight
400 kg/m2
U-value
≈ 0.245 W/m2K
GWP
92.70 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of solid timber, derived wood product, double sheathed, without ceiling covering, without dampening in the supporting structure, without cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 0.2 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 68 dB
C -2 dB
C50-3150 -3 dB
Values of footfall sound insulation
Ln,w 46 dB
CI -2 dB
CI50-2500 1 dB

Graphic

On-lying material: Cement screed
Impact sound insulation: Akustic EP1
Dampening on Supporting structure: Edelsplitt 2-5mm gebunden mit StoPrefa Coll SB
Sub-floor: Trickling protection
Bond: no composite action
Supporting structure: SWISS KRONO MAGNUMBOARD OSB
Lower skin layer 1: GM-F Knauf Fireboard with Fliesskaschierung
Lower skin 2nd layer: GM-F Knauf Fireboard with Fliesskaschierung

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Cement screed Generic product 50 mm 110 kg/m2 - - 04.006 91.136
Impact sound insulation Akustic EP1 Isover 35 mm 2.5 kg/m2 - - 10.001.01 91.173
Dampening on Supporting structure Edelsplitt 2-5mm gebunden mit StoPrefa Coll SB Sto 90 mm 148.5 kg/m2 - - 03.011 91.062
Sub-floor Trickling protection Generic product 0.5 mm 0.4 kg/m2 - - 09.007 91.037
Bond no composite action - - - - - - -
Supporting structure SWISS KRONO MAGNUMBOARD OSB Willisauerstrasse 37, Wittstocker Chaussee 1 175 mm 115.5 kg/m2 1000 mm 1000 mm 07.013 91.145
Lower skin layer 1 GM-F Knauf Fireboard with Fliesskaschierung Knauf 15 mm 11.7 kg/m2 - - 03.008 91.064
Lower skin 2nd layer GM-F Knauf Fireboard with Fliesskaschierung Knauf 15 mm 11.7 kg/m2 - - 03.008 91.064

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 31 46 46 49 53 53 53 54 55 58 65 70 77 80 84 86 84 85 91 90 83
Calculation Lignum/Kühn and Blickle 33 36 39 41 44 47 48 48 44 47 44 47 49 52 52 52 52 61 70 77 86 95
Impact sound (Ln) Measurement Ift Rosenheim 57 50 47 43 44 45 46 49 51 52 51 49 44 42 41 37 36 35 28 22 13
Calculation Lignum/Kühn and Blickle 47 48 48 48 49 50 51 54 61 61 67 67 68 68 71 74 77 71 65 61 55 49

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
170857
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
144557.1
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
26020.5
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1375.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1347.7
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
687.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
655.2
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
28.5
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
967.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
965.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
377.5
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
587.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.4
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
405
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
377.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
311.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
66.7
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
27.1
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
92.7
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
78.4
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
14.2
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
189.5666666666667
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
51.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)