LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly C0074

Lignum ID-№
C0074
Catalog number
C.1.01.N0
Source of construction assembly
Lignum, Year 2016
Base structure
Stud
Sheathing
Sheathed on both sides
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1, Tabelle: 442
Construction height
170 mm
Weight
29 kg/m2
U-value
≈ 0.251 W/m2K
GWP
12.60 kg CO2-eq/m2
Type sound insulation
Verified calculation
Partition wall single shellconsisting of a basic construction ofstud with cavity insulation in the supporting structure with air flow resistivity [r] of 5≤ r ≤50 kPa s/m². Sheathed on both sides, leftside single sheathed, rightside single sheathed. Without covering.
Values of airborne sound insulation
Rw 39 dB
C -2 dB
C50-3150 -9 dB

Graphic

Sheathed leftside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³
Bond: Stiff, execution of the prior art.
Support: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤50 [kPa * s/m]
Bond: Stiff, execution of the prior art.
Sheathed rightside 1st layer: Wood panel for structural purposes ≥ 600 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
Sheathed leftside 1st layer Wood panel for structural purposes ≥ 600 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 15 mm 9 kg/m2 - - 07.013 91.145
Bond Stiff, execution of the prior art. - - - - - - -
Support Rib/bar Generic product, Label swiss wood 140 mm 6.6 kg/m2 60 mm 625 mm 07.003.01 91.047
Cavity dampening Fiber insulation with 5≤ r ≤50 [kPa * s/m] Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 140 mm 4.5 kg/m2 - - 10.008 91.173
Bond Stiff, execution of the prior art. - - - - - - -
Sheathed rightside 1st layer Wood panel for structural purposes ≥ 600 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 15 mm 9 kg/m2 - - 07.013 91.145

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
24284
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
21741
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
2501
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
263.20
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
260.60
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
124.30
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
135.50
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
2.60
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
203.00
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
202.70
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
77.50
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
125.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.20
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
59.70
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
57.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
47.10
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
10.20
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
2.50
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
12.60
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
10.70
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
1.80
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
0.00
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
10.90
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)