Components

Construction assembly A0441

Lignum ID-№
A0441
Catalog number
A.2.03.A16
Source of construction assembly
Lignum, Year 2016
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 433
Construction height
395 mm
Weight
158 kg/m2
U-value
≈ 0.352 W/m2K
GWP
38.10 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering with air flow resistivity [r] of 5≤ r ≤35 kPa s/m², without dampening in the supporting structure, with cavity insulation in the supporting structure. With dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 30 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 54 dB
C -2 dB
C50-3150 -3 dB
Values of footfall sound insulation
Ln,w 61 dB
CI 0 dB
CI50-2500 1 dB

Graphic

On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Dampening on Supporting structure: Dampening gravel ≤ 1400 kg/m³
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Rigid, execution of the prior art.
Supporting structure: Rib/bar
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Bond: Rigid, execution of the prior art.
Lower skin layer 1: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 23 mm 28.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] Gutex, Isover 22 mm 3.5 kg/m2 - - 10.009 91.051
Dampening on Supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 60 mm 84 kg/m2 - - 03.011 91.062
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048
Bond Rigid, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 240 mm 15.1 kg/m2 80 mm 625 mm 07.003.01 91.047
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 160 mm 4.5 kg/m2 - - 10.008 91.173
Bond Rigid, execution of the prior art. - - - - - - -
Lower skin layer 1 Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 28 30 32 33 31 33 39 45 51 56 61 66 70 75 80 85 89 97 104
Calculation Lignum/Kühn and Blickle 22 25 27 30 33 35 37 36 39 42 45 47 50 52 53 53 53 62 71 78 87 95
Impact sound (Ln) Measurement Lignum Berechnung 61 62 63 65 70 71 68 65 62 60 57 56 55 53 51 49 48 43 39
Calculation Lignum/Kühn and Blickle 59 59 60 60 60 61 62 65 66 66 66 67 67 68 70 74 76 70 65 60 54 49

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
75126.2
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
65455.5
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
9714.4
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
639.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
628
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
407.5
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
222.5
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
11.9
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
468.9
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
468.4
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
255.9
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
211.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.6
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
172.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
161.5
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
150.4
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
11.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
11.3
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
38.1
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
33.9
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
4.2
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
72.23333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
19.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)