LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0453

Lignum ID-№
A0453
Catalog number
A.2.03.A26
Source of construction assembly
Lignum, Year 2016
Base structure
Hollow box element
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 433 Gilt nicht für Bauteile mit Beschwerung im Hohlraum.
Construction height
335 mm
Weight
265 kg/m2
U-value
≈ 0.389 W/m2K
GWP
36.40 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of hollow box element, without sheathing, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 30 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 58 dB
C -3 dB
C50-3150 -3 dB
Values of footfall sound insulation
Ln,w 57 dB
CI 0 dB
CI50-2500 1 dB

Graphic

On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Sub-floor: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³
Bond: Rigid, execution of the prior art.
Supporting structure: Rib/bar
Dampening in supporting structure: Dampening gravel ≤ 1400 kg/m³
Bond: Rigid, execution of the prior art.
Lower skin layer 1: Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 23 mm 28.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] Gutex, Isover 22 mm 3.5 kg/m2 - - 10.009 91.051
Sub-floor Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048
Bond Rigid, execution of the prior art. - - - - - - -
Supporting structure Rib/bar Generic product, Label swiss wood 240 mm 15.1 kg/m2 80 mm 625 mm 07.003.01 91.047
Dampening in supporting structure Dampening gravel ≤ 1400 kg/m³ Fermacell, Zisola 160 mm 195.3 kg/m2 - - 03.011 91.062
Bond Rigid, execution of the prior art. - - - - - - -
Lower skin layer 1 Multilayer solid wood panels, engineered wood panel ≥ 450 kg/m³ Willisauerstrasse 37, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Schilliger Holz 25 mm 11.8 kg/m2 - - 07.001 91.048

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 31 33 36 37 35 37 43 49 55 60 65 70 74 79 84 89 93 101 108
Calculation Lignum/Kühn and Blickle 26 29 32 34 37 40 41 41 43 46 49 52 54 56 57 57 57 66 75 82 91 100
Impact sound (Ln) Measurement Lignum Berechnung 58 58 59 61 66 67 64 67 58 56 53 52 51 49 48 45 44 39 35
Calculation Lignum/Kühn and Blickle 55 55 56 56 56 57 58 61 62 62 62 62 63 63 66 69 72 66 60 56 50 44

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
76268.39999999998
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
62658
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
13671.9
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
628.2
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
611.1
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
390.6
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
222.5
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
17.4
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
462.4
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
461.7
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
249.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
211.3
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.8
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
167.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
151.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
140.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
11.1
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
16.6
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
36.4
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
31.1
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
5.4
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
72.23333333333333
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
19.7
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)