LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A0901

Lignum ID-№
A0901
Catalog number
A.3.02.L50
Source of construction assembly
Lignum, Year 2016
Base structure
Solid wood panel
Paneling
Substructure with rubber-mounted hangers
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 434/5/6
Construction height
395 mm
Weight
161 kg/m2
U-value
≈ 0.201 W/m2K
GWP
66.30 kg CO2-eq/m2
Type sound insulation
Verified calculation
Ceiling consisting of a basic construction of solid timber, without sheathing, double ceiling covering. Substructure mounted with flexible hangers with cavity insulation, without dampening in the supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 30 MN/m³ and with dry screed.
Values of airborne sound insulation
Rw 69 dB
C -3 dB
C50-3150 -9 dB
Values of footfall sound insulation
Ln,w 46 dB
CI 0 dB
CI50-2500 8 dB

Graphic

On-lying material: Floor heating system Therm38 longitudinal grooves
Impact sound insulation: Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²]
Supporting structure: Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³
Bond: no composite action
Coupling: Rubber mounted direct hanger b=60mm
Battens / profiles: CD-ceiling profile b=60mm
Cavity dampening: Fiber insulation with 5≤ r ≤35 [kPa*s/m²
Ceiling covering 1st layer: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Ceiling covering layer 2: Gypsum fiber or hard gypsum board ≥ 1000kg/m³
Surface / treatment: Glued joints/smoothed

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal
On-lying material Floor heating system Therm38 longitudinal grooves Fermacell, Knauf, Rigips 23 mm 28.3 kg/m2 - - 03.007 91.063
Impact sound insulation Wood fiber with dynamic stiffness s' of ≤ 30 [MN / m²] Gutex, Isover 22 mm 3.5 kg/m2 - - 10.009 91.051
Supporting structure Wood panel for structural purposes, Cross laminated timber, laminated timber ≥ 450 kg/m³ Swiss Krono, Pius Schuler, Stora Enso, Binderholz, Novatop, Pfleiderer, Kaufmann Oberholzer, Tschopp, Sidler Holz, Egg Holz Kälin, Schilliger Holz 200 mm 94 kg/m2 1000 mm 1000 mm 07.002 91.047
Bond no composite action - - - - - - -
Coupling Rubber mounted direct hanger b=60mm Ampack, Fermacell, Knauf, Rigips, Protektor 93 mm - - 729 mm - -
Battens / profiles CD-ceiling profile b=60mm Fermacell, Knauf, Rigips, Protektor 27 mm 1.1 kg/m2 60 mm 500 mm 06.011 91.143
Cavity dampening Fiber insulation with 5≤ r ≤35 [kPa*s/m² Flumroc, Isover, Sager, Swisspor, Gutex, Isofloc, Schilliger Holz 80 mm 2.6 kg/m2 - - 10.008 91.173
Ceiling covering 1st layer Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Ceiling covering layer 2 Gypsum fiber or hard gypsum board ≥ 1000kg/m³ Fermacell, Knauf, Rigips 15 mm 16 kg/m2 - - 03.007 91.063
Surface / treatment Glued joints/smoothed Fermacell, Knauf, Rigips - - - - - -

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Lignum Berechnung 23 31 37 42 44 49 57 67 76 85 93 101 109 110 110 110 110 110 110
Calculation Lignum/Kühn and Blickle 28 30 31 31 32 41 48 52 53 59 60 66 72 79 84 90 95 101 107 110 110 110
Impact sound (Ln) Measurement Lignum Berechnung 66 61 58 56 57 55 50 43 37 31 26 21 16 12 7 1 1 1 1
Calculation Lignum/Kühn and Blickle 53 54 56 59 61 55 51 50 52 49 51 48 45 41 39 36 34 31 28 25 19 14

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to KBOB Ökobilanzdaten im Baubereich
(Manufacture and disposal, without considering the payback periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
140944.5
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
128604.3
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
12318.8
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
1086.8
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
1071.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
563.9
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
507.9
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
15
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
789.1
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
787.8
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
290.2
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
497.6
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
0.9
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
297.7
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
283.6
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
274.2
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
9.8
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
14.1
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
66.3
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
60
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
6.2
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
169.76666666666665
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
46.3
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)